Yayın: Effects of geometrical parameters on the pressure drop for a modified cyclone separator
| dc.contributor.buuauthor | Tan, Fuat | |
| dc.contributor.buuauthor | Karagöz, İrfan | |
| dc.contributor.buuauthor | Avcı, Atakan | |
| dc.contributor.department | Mühendislik Fakültesi | |
| dc.contributor.department | Makine Mühendisliği Bölümü | |
| dc.contributor.researcherid | AAB-9388-2020 | |
| dc.contributor.scopusid | 57131310700 | |
| dc.contributor.scopusid | 56785809700 | |
| dc.contributor.scopusid | 7004169972 | |
| dc.date.accessioned | 2022-11-28T08:52:09Z | |
| dc.date.available | 2022-11-28T08:52:09Z | |
| dc.date.issued | 2015-12-17 | |
| dc.description.abstract | Experimental results for a conventional cyclone and a modified cyclone with an adjustable vortex stopper are presented. The modified design is based on the idea of decreasing the surface friction by leaving a separation space between the cylindrical part and the vortex stopper. The measured pressure losses were compared for various exit pipe diameters, cylinder heights, cone bottom diameters, and inlet velocities for the conventional as well as for the modified design. The comparative studies indicate a similar behavior of the pressure loss coefficient for both cyclones. Additionally, the exit pipe diameter has a more significant effect on both cyclones compared to the other parameters. Increasing the length of the cyclone reduced the pressure losses for all cases examined. | |
| dc.identifier.citation | Tan, F. vd. (2016). "Effects of geometrical parameters on the pressure drop for a modified cyclone separator". Chemical Engineering and Technology, 39(3), Special Issue, 576-581. | |
| dc.identifier.doi | 10.1002/ceat.201500182 | |
| dc.identifier.endpage | 581 | |
| dc.identifier.issn | 0930-7516 | |
| dc.identifier.issn | 1521-4125 | |
| dc.identifier.issue | 3, Special Issue | |
| dc.identifier.scopus | 2-s2.0-84958882263 | |
| dc.identifier.startpage | 576 | |
| dc.identifier.uri | https://doi.org/10.1002/ceat.201500182 | |
| dc.identifier.uri | https://onlinelibrary.wiley.com/doi/10.1002/ceat.201500182 | |
| dc.identifier.uri | http://hdl.handle.net/11452/29591 | |
| dc.identifier.volume | 39 | |
| dc.identifier.wos | 000372960900025 | |
| dc.indexed.wos | SCIE | |
| dc.language.iso | en | |
| dc.publisher | Wiley-V C H | |
| dc.relation.journal | Chemical Engineering and Technology | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | |
| dc.relation.tubitak | 114M591 | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Engineering | |
| dc.subject | Cyclone | |
| dc.subject | Pressure drop | |
| dc.subject | Separation techniques | |
| dc.subject | Swirl flow | |
| dc.subject | Vortex finder | |
| dc.subject | Collection efficiency | |
| dc.subject | Numerical-simulation | |
| dc.subject | Performance | |
| dc.subject | Flow | |
| dc.subject | Hydrocyclone | |
| dc.subject | Optimization | |
| dc.subject | Design | |
| dc.subject | Length | |
| dc.subject | Geometry | |
| dc.subject | Piping systems | |
| dc.subject | Storms | |
| dc.subject | Vortex flow | |
| dc.subject | Comparative studies | |
| dc.subject | Cylinder heights | |
| dc.subject | Modified designs | |
| dc.subject | Pressure loss coefficient | |
| dc.subject | Separation space | |
| dc.subject | Surface friction | |
| dc.subject | Drops | |
| dc.subject.scopus | Cyclone Separators; Gas; Pressure Drop | |
| dc.subject.wos | Engineering, chemical | |
| dc.title | Effects of geometrical parameters on the pressure drop for a modified cyclone separator | |
| dc.type | Article | |
| dc.wos.quartile | Q2 | |
| dspace.entity.type | Publication | |
| local.contributor.department | Mühendislik Fakültesi/Makine Mühendisliği Bölümü | |
| local.indexed.at | Scopus | |
| local.indexed.at | WOS |
Dosyalar
Lisanslı seri
1 - 1 / 1