Yayın: Effects of geometrical parameters on the pressure drop for a modified cyclone separator
Tarih
Kurum Yazarları
Tan, Fuat
Karagöz, İrfan
Avcı, Atakan
Yazarlar
Danışman
Dil
Türü
Yayıncı:
Wiley-V C H
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Özet
Experimental results for a conventional cyclone and a modified cyclone with an adjustable vortex stopper are presented. The modified design is based on the idea of decreasing the surface friction by leaving a separation space between the cylindrical part and the vortex stopper. The measured pressure losses were compared for various exit pipe diameters, cylinder heights, cone bottom diameters, and inlet velocities for the conventional as well as for the modified design. The comparative studies indicate a similar behavior of the pressure loss coefficient for both cyclones. Additionally, the exit pipe diameter has a more significant effect on both cyclones compared to the other parameters. Increasing the length of the cyclone reduced the pressure losses for all cases examined.
Açıklama
Kaynak:
Anahtar Kelimeler:
Konusu
Engineering, Cyclone, Pressure drop, Separation techniques, Swirl flow, Vortex finder, Collection efficiency, Numerical-simulation, Performance, Flow, Hydrocyclone, Optimization, Design, Length, Geometry, Piping systems, Storms, Vortex flow, Comparative studies, Cylinder heights, Modified designs, Pressure loss coefficient, Separation space, Surface friction, Drops
Alıntı
Tan, F. vd. (2016). "Effects of geometrical parameters on the pressure drop for a modified cyclone separator". Chemical Engineering and Technology, 39(3), Special Issue, 576-581.