| dc.description.abstract | In this research, the physico-chemical treatability of landfill leachate with domestic wastewater was investigated. For the physico-chemical treatments, leachate was pretreated using lime, ammonia stripping, Iron (III) chloride (FeCl3.6H2O) or aluminum sulphate (Al2(SO4)3·18H2O). Chemical oxygen demand (COD) removal efficiencies of 35%, 55% and 59% were obtained for pre-treatment with lime, FeCl3.6H2O and Al2(SO4)3·18H2O, respectively. Raw leachate was mixed with activated sludge at mixture ratios of 1/1, 1/2, 2/1, 2%, 5% and 10% (v/v), and a 1343% increase in the respiration activity was obtained for the 2% mixture ratio. Respiration activity values increased by 1462% and 1326% for the mixture ratios of 5% and 10%, respectively, of domestic wastewater with leachate that was pre-treated with lime and ammonia stripping. Based on the respirometric measurements, it was concluded that leachate pre-treated with lime and ammonia stripped can be economically treated with domestic wastewater. | |
| dc.identifier.endpage | 250 | |
| dc.identifier.isbn | [9781634833967, 9781634834056] | |
| dc.identifier.scopus | 2-s2.0-84956841068 | |
| dc.identifier.startpage | 237 | |
| dc.identifier.uri | https://hdl.handle.net/11452/53704 | |
| dc.indexed.scopus | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Nova Science Publishers, Inc. | |
| dc.relation.journal | Physical Chemical and Biological Treatment Processes for Water and Wastewater | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Respirometric method | |
| dc.subject | Landfill leachate | |
| dc.subject | Chemical treatment | |
| dc.subject | Ammonia stripping | |
| dc.subject | Domestic wastewater | |
| dc.title | Monitoring the combined treatment of landfill leachate with domestic wastewater using a respirometric method | |
| dc.type | Book Chapter | |
| dspace.entity.type | Publication | |
| local.contributor.department | Mühendislik Fakültesi/Çevre Mühendisliği Bölümü | |
| local.indexed.at | Scopus | |
| relation.isAuthorOfPublication | 9847e914-244a-4fb4-9981-001d1a5d0af7 | |
| relation.isAuthorOfPublication.latestForDiscovery | 9847e914-244a-4fb4-9981-001d1a5d0af7 |