Publication:
Full geant4 and FLUKA simulations of an e-LINAC for its use in particle detectors performance tests

dc.contributor.authorAlpat, Behçet
dc.contributor.authorServoli, Leonello
dc.contributor.authorBuono, Eduardo
dc.contributor.authorDi Capua, Francesco
dc.contributor.authorMenichelli, Mauro
dc.contributor.authorTucceri, Paola
dc.contributor.authorItaliani, Marco
dc.contributor.buuauthorPiliçer, Ercan
dc.contributor.departmentFen Edebiyat Fakültesi
dc.contributor.departmentFizik Bölümü
dc.contributor.scopusid15843878300
dc.date.accessioned2022-05-12T12:42:32Z
dc.date.available2022-05-12T12:42:32Z
dc.date.issued2012-03
dc.description.abstractIn this work we present the results of full Geant4 and FLUKA simulations and comparison with dosimetry data of an electron LINAC of St. Maria Hospital located in Terni, Italy. The facility is being used primarily for radiotherapy and the goal of the present study is the detailed investigation of electron beam parameters to evaluate the possibility to use the e-LINAC (during time slots when it is not used for radiotherapy) to test the performance of detector systems, in particular those designed to operate in space. The critical beam parameters are electron energy, profile and flux available at the surface of device to be tested. The present work aims to extract these parameters from dosimetry calibration data available at the e-LINAC. The electron energy ranges from 4 MeV to 20 MeV. The dose measurements have been performed by using an Advanced Markus Chamber which has a small sensitive volume.
dc.identifier.citationAlpat, B. vd. (2012). "Full geant4 and FLUKA simulations of an e-LINAC for its use in particle detectors performance tests". Journal of Instrumentation, 7,1-9.
dc.identifier.endpage9
dc.identifier.issn1748-0221
dc.identifier.scopus2-s2.0-84859586435
dc.identifier.startpage1
dc.identifier.urihttps://doi.org/10.1088/1748-0221/7/03/P03013
dc.identifier.urihttps://iopscience.iop.org/article/10.1088/1748-0221/7/03/P03013
dc.identifier.urihttp://hdl.handle.net/11452/26432
dc.identifier.volume7
dc.identifier.wos000304015300061
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherIOP Publishing
dc.relation.collaborationYurtdışı
dc.relation.journalJournal of Instrumentation
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectInstruments & instrumentation
dc.subjectDosimetry concepts and apparatus
dc.subjectPerformance of high energy physics detectors
dc.subjectSimulation methods and programs
dc.subjectParticle tracking detectors (solid-state detectors)
dc.subject.scopusActive Pixel Sensor; CMOS; Silicon-On-Insulator
dc.subject.wosInstruments & instrumentation
dc.titleFull geant4 and FLUKA simulations of an e-LINAC for its use in particle detectors performance tests
dc.typeArticle
dc.wos.quartileQ2
dspace.entity.typePublication
local.contributor.departmentFen Edebiyat Fakültesi/Fizik Bölümü
local.indexed.atScopus
local.indexed.atWOS

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Piliçer_vd_2012.pdf
Size:
308.18 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: