Yayın: Parametric study and thermal sensitivity analysis of a triple effect absorption refrigeration system
| dc.contributor.author | Saka, Kenan | |
| dc.contributor.author | Orhan, Mehmet Fatih | |
| dc.contributor.buuauthor | SAKA, KENAN | |
| dc.contributor.department | Yenişehir İbrahim Orhan Meslek Yüksekokulu | |
| dc.contributor.department | Makine ve Metal Teknolojileri | |
| dc.contributor.researcherid | AAH-5303-2021 | |
| dc.date.accessioned | 2025-11-06T16:42:38Z | |
| dc.date.issued | 2025-03-21 | |
| dc.description.abstract | Absorption refrigeration systems represent an efficient means of cooling utilizing waste heat, with triple-effect absorption refrigeration systems outperforming their double and single-effect counterparts in terms of efficiency. This study conducts energy and exergy analyses on a triple-effect absorption refrigeration system, focusing on internal heat balance and thermal sensitivity to maximize efficiency. The analysis pinpointed the most sensitive thermal sensitivity areas within the system, highlighting the high-pressure condenser (HPC) outlet and medium-pressure condenser (MPC) outlet as critical points. Notably, increasing the temperatures of HPC and MPC leads to enhanced COP and ECOP, with a mere 5 K rise in HPC exit temperature resulting in a remarkable 57 % boost in system performance. Similarly, elevating the MPC operating temperature by 5 K yields a significant 34 % improvement in COP value. | |
| dc.identifier.doi | 10.1016/j.csite.2025.106030 | |
| dc.identifier.issn | 2214-157X | |
| dc.identifier.scopus | 2-s2.0-105000277621 | |
| dc.identifier.uri | https://doi.org/10.1016/j.csite.2025.106030 | |
| dc.identifier.uri | https://hdl.handle.net/11452/56594 | |
| dc.identifier.volume | 69 | |
| dc.identifier.wos | 001456260000001 | |
| dc.indexed.wos | WOS.SCI | |
| dc.language.iso | en | |
| dc.publisher | Elsevier | |
| dc.relation.journal | Case Studies İn Thermal Engineering | |
| dc.subject | Single | |
| dc.subject | Cycle | |
| dc.subject | Optimization | |
| dc.subject | Triple effect absorption refrigeration system | |
| dc.subject | Series flow | |
| dc.subject | Energy analysis | |
| dc.subject | Exergy | |
| dc.subject | Internal condensers | |
| dc.subject | Thermodynamics | |
| dc.subject | Physical sciences | |
| dc.subject | Science & Technology | |
| dc.title | Parametric study and thermal sensitivity analysis of a triple effect absorption refrigeration system | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.contributor.department | Yenişehir İbrahim Orhan Meslek Yüksekokulu/Makine ve Metal Teknolojileri | |
| local.indexed.at | WOS | |
| local.indexed.at | Scopus | |
| relation.isAuthorOfPublication | 71b67ffd-8bd5-46d4-a9c8-3395c028402c | |
| relation.isAuthorOfPublication.latestForDiscovery | 71b67ffd-8bd5-46d4-a9c8-3395c028402c |