Publication: Determination of full energy peak efficiency of HpGe detector from 59.5 to 1332.5 keV
dc.contributor.buuauthor | Gültekin, Ali Haydar | |
dc.contributor.buuauthor | Kaynak, Gökay | |
dc.contributor.buuauthor | Gürler, Orhan | |
dc.contributor.department | Fen Edebiyat Fakültesi | |
dc.contributor.researcherid | AAH-1837-2021 | |
dc.contributor.scopusid | 7004173605 | |
dc.contributor.scopusid | 12042075600 | |
dc.contributor.scopusid | 14019444500 | |
dc.date.accessioned | 2021-12-09T05:53:47Z | |
dc.date.available | 2021-12-09T05:53:47Z | |
dc.date.issued | 2006-04 | |
dc.description.abstract | To detect very low radio activities in the environmental samples, it is sometimes necessary to know the full energy peak efficiency of the detector. This work proposes a full energy peak efficiency simulation which represents adequately the high purity germanium coaxial detector responses in the energy range 59.5-1332.5 keV and at distances of 5, 10 and 25 cm. | |
dc.identifier.citation | Gültekin, A. H. vd. (2006). ''Determination of full energy peak efficiency of HpGe detector from 59.5 to 1332.5 keV''. Indian Journal of Pure and Applied Physics, 44(4), 281-286. | |
dc.identifier.endpage | 286 | |
dc.identifier.issn | 0019-5596 | |
dc.identifier.issn | 0975-1041 | |
dc.identifier.issue | 4 | |
dc.identifier.scopus | 2-s2.0-33749159858 | |
dc.identifier.startpage | 281 | |
dc.identifier.uri | http://hdl.handle.net/11452/23100 | |
dc.identifier.volume | 44 | |
dc.identifier.wos | 000237330400001 | |
dc.indexed.wos | SCIE | |
dc.language.iso | en | |
dc.publisher | Natl Inst Science Communication - Niscair | |
dc.relation.journal | Indian Journal of Pure and Applied Physics | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.subject | Physics | |
dc.subject | Monte Carlo simulation | |
dc.subject | HpGe detector | |
dc.subject | Efficiency | |
dc.subject | Calibration | |
dc.subject | Samples | |
dc.subject | Simulation | |
dc.subject | Gamma-ray | |
dc.subject | Coincidence corrections | |
dc.subject | Monte-carlo method | |
dc.subject | Including self-absorption | |
dc.subject.scopus | Gamma Spectrometry; Radiation Detectors; Thallium-Doped Sodium Iodide | |
dc.subject.wos | Physics, multidisciplinary | |
dc.title | Determination of full energy peak efficiency of HpGe detector from 59.5 to 1332.5 keV | |
dc.type | Article | |
dc.wos.quartile | Q4 | |
dspace.entity.type | Publication | |
local.contributor.department | Fen Edebiyat Fakültesi | |
local.indexed.at | Scopus | |
local.indexed.at | WOS |
Files
License bundle
1 - 1 of 1
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: