Publication:
Investigation of the basic dimensional properties and biomechanical performance of artificial ACL grafts produced by 3-D braiding method

dc.contributor.authorTurşucular, Ömer Fırat
dc.contributor.buuauthorTurşucular, Ömer Fırat
dc.contributor.departmentTekstil Mühendisliği Bölümü
dc.contributor.departmentFen Bilimleri Enstitüsü
dc.contributor.scopusid57204128119
dc.date.accessioned2025-05-12T22:36:42Z
dc.date.issued2024-01-01
dc.description.abstractIn the current study, an investigation of basic dimensional properties and biomechanical performance of artificial ACL grafts produced by the 3-D braiding method was carried out. Artificial ACL grafts were produced using the 3-D braiding process. All 3-D braiding grafts were produced using various technical yarns for raw and bio-finishing grafts. Ethylene oxide (EtO) sterilization was applied to all grafts. The effects of yarn types, yarn counts, and 3-D braiding constructions on EtO sterilized raw and bio-finished artificial ACL grafts were examined. In conclusion; the tensile strength and thickness values of all 3-D braiding structured ACL grafts were suitable for artificial ligament grafts. Additionally, its grammage values were extremely light. The yarn type, yarn count, and 3-D braiding construction were the most effective process parameters on thickness, grammage, and tensile strength values. They can be improved by using x2-layered 3-D braiding structures, thicker yarn counts, and more than 1 core yarn in similar studies to be conducted in the future.
dc.identifier.doi10.31881/TLR.2023.176
dc.identifier.endpage87
dc.identifier.issn2623-6257
dc.identifier.scopus2-s2.0-85183587686
dc.identifier.startpage62
dc.identifier.urihttps://hdl.handle.net/11452/51395
dc.identifier.volume7
dc.indexed.scopusScopus
dc.language.isoen
dc.publisheridd3
dc.relation.journalTextile and Leather Review
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDimensional properties
dc.subjectBiomechanical performance
dc.subjectBio-finishing
dc.subjectACL graft
dc.subject3-D braiding
dc.subject.scopusAnterior Cruciate Ligament Reconstruction; Polyethylene Terephthalate; Knee Joint
dc.titleInvestigation of the basic dimensional properties and biomechanical performance of artificial ACL grafts produced by 3-D braiding method
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentFen Bilimleri Enstitüsü/Tekstil Mühendisliği Bölümü

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Turşucular_2024.pdf
Size:
1.83 MB
Format:
Adobe Portable Document Format

Collections