Publication:
Dosimetric control of dose distribution calculated in computerized treatment planning system

dc.contributor.buuauthorGÜRLER, ORHAN
dc.contributor.buuauthorŞahin, Sevim
dc.contributor.buuauthorGürler, Orhan
dc.contributor.buuauthorGözcü, Sema
dc.contributor.buuauthorKurt, Meral
dc.contributor.buuauthorKURT, MERAL
dc.contributor.buuauthorŞengül, Kansu
dc.contributor.buuauthorAltay, Ali
dc.contributor.buuauthorKahraman Çetintaş, Sibel
dc.contributor.buuauthorÖzkan, Lütfi
dc.contributor.departmentBursa Uludağ Üniversitesi/Tıp Fakültesi/Radyasyon Onkolojisi Anabilim Dalı.
dc.contributor.departmentBursa Uludağ Üniversitesi/Fen Edebiyat Fakültesi/Fizik Bölümü.
dc.contributor.orcid0000-0002-9968-0119
dc.contributor.researcheridAAB-4181-2020
dc.contributor.researcheridACU-4827-2022
dc.contributor.researcheridAAH-1837-2021
dc.contributor.researcheridAAA-3961-2020
dc.date.accessioned2024-10-01T08:29:11Z
dc.date.available2024-10-01T08:29:11Z
dc.date.issued2011-01-01
dc.description.abstractOBJECTIVESThe purpose of this study is providing dosimetric control by comparing dose values calculated in computerized treatment planning system (CTPS) and measured by Linear 2D-Array and ion chambers of various volumes.METHODSFields measured by Farmer, Semiflex and PinPoint ion chambers were created in CTPS. Using Linear 2D-Array, measurements were done in open, isocentric, oblique and wedge filtered fields which created in CTPS. Dose values were compared.RESULTSPinPoint ion chamber measured top dose values whereas Farmer ion chamber measured low values. The most compatible results with CTPS were obtained by Semiflex ion chamber. However, in 2D-Array measurements, concordance was observed with CTPS in central axis, difference reached 20 % in build-up and penumbra regions.CONCLUSIONThe most compatible results with CTPS were obtained by Semiflex ion chamber. Reasons of discordance in 2D-Array measurements were found as; varible dose around build-up region, and not to obtain the exact superpose of profiles' penumbra region.
dc.identifier.doi10.5505/tjoncol.2011.597
dc.identifier.endpage173
dc.identifier.issn1300-7467
dc.identifier.issue4
dc.identifier.startpage167
dc.identifier.urihttps://doi.org/10.5505/tjoncol.2011.597
dc.identifier.urihttps://hdl.handle.net/11452/45584
dc.identifier.volume26
dc.identifier.wos000439265500004
dc.indexed.wosWOS.ESCI
dc.language.isoen
dc.publisherKare Publ
dc.relation.journalTurk Onkoloji Dergisi-turkish Journal Of Oncology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectComputerized treatment planning system
dc.subjectLinear 2d-array
dc.subjectQuality assurence in radiotherapy
dc.subjectScience & technology
dc.subjectLife sciences & biomedicine
dc.subjectOncology
dc.titleDosimetric control of dose distribution calculated in computerized treatment planning system
dc.typeArticle
dspace.entity.typePublication
relation.isAuthorOfPublicationbca54357-e126-4dbd-bab8-72da6e159876
relation.isAuthorOfPublication46f06dde-5b49-4013-b721-4e146d624e0e
relation.isAuthorOfPublication.latestForDiscovery46f06dde-5b49-4013-b721-4e146d624e0e

Files

Collections