Publication:
Effects of fat accumulation in the liver on hemodynamic variables assessed by Doppler ultrasonography

dc.contributor.buuauthorTopal, Naile Bolca
dc.contributor.buuauthorOrcan, Serap
dc.contributor.buuauthorSığırlı, Deniz
dc.contributor.buuauthorOrcan, Gökhan
dc.contributor.buuauthorEritmen, Ülkü
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentBiyoistatistik Ana Bilim Dalı
dc.contributor.departmentRadyoloji Ana Bilim Dalı
dc.contributor.researcheridAAI-2327-2021
dc.contributor.researcheridDKR-9813-2022
dc.contributor.researcheridFSE-6855-2022
dc.contributor.researcheridILJ-9789-2023
dc.contributor.scopusid13806674200
dc.contributor.scopusid56174250500
dc.contributor.scopusid24482063400
dc.contributor.scopusid56173683700
dc.contributor.scopusid56173666500
dc.date.accessioned2024-02-19T13:29:10Z
dc.date.available2024-02-19T13:29:10Z
dc.date.issued2015-01-01
dc.description.abstractPurposeTo investigate the effect of various degrees of fatty liver infiltration on hepatic hemodynamics using Doppler ultrasonography. MethodsWe included 40 patients with hepatic steatosis and 20 healthy volunteers. Hepatic steatosis was quantified by a chemical shift MRI. Hepatic artery peak systolic and end-diastolic velocity, resistance index (RI) and pulsatility index (PI), hepatic vein RI and PI, portal vein RI, PI, congestion index, and peak maximum velocity were evaluated by Doppler ultrasonography. The hepatic vein waveforms were classified as triphasic, biphasic, or monophasic. Kruskal-Wallis test was performed for comparing more than two groups. If significant differences were found, Mann-Whitney U test with Bonferroni correction was performed for pair-wise comparisons. Pearson & gch;(2) and Fisher's exact tests were used to compare categorical variables. ResultsAccording to MRI, 15 patients had mild, 14 patients had moderate, and 11 patients had severe fatty infiltration. Portal vein peak maximum velocity was median: 19.8 (range 12-33.3), 21.1 (8-41.8), 16.6 (10.6-24.9), and 29.2 (14.1-40.4) cm/s. Congestion index was 0.05 (0.02-0.16), 0.07 (0.01-0.17), 0.11 (0.06-0.24), and 0.05 (0.02-0.16). Hepatic artery RI was 0.75 (0.56-1.00), 0.66 (0.52-0.87), 0.83 (0.38-1.00), and 0.76 (0.48-2.76), and PI was 1.83 (0.90-3.13), 1.38 (1.04-2.63), 1.97 (0.86-2.90), and 1.82 (0.70-2.90) (p=.046 and p=.036) in the mild, moderate, severe steatosis, and control groups, respectively. The rate of triphasic hepatic vein waveforms was higher in controls than in patients with severe steatosis. ConclusionsPortal vein flow velocity decreases in severe hepatic steatosis when compared with controls.
dc.identifier.citationTopal, N. B. vd. (2015). "Effects of fat accumulation in the liver on hemodynamic variables assessed by Doppler ultrasonography". Journal of Clinical Ultrasound, 43(1), 26-33.
dc.identifier.endpage33
dc.identifier.issn0091-2751
dc.identifier.issue1
dc.identifier.pubmed24867781
dc.identifier.scopus2-s2.0-84915754885
dc.identifier.startpage26
dc.identifier.urihttps://doi.org/10.1002/jcu.22157
dc.identifier.urihttps://onlinelibrary.wiley.com/doi/10.1002/jcu.22157
dc.identifier.urihttps://hdl.handle.net/11452/39855
dc.identifier.volume43
dc.identifier.wos000346065300005
dc.indexed.scopusScopus
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherWiley
dc.relation.journalJournal of Clinical Ultrasound
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectAcoustics
dc.subjectRadiology, nuclear medicine & medical imaging
dc.subjectHepatosteatosis
dc.subjectDoppler US
dc.subjectHepatic artery
dc.subjectHepatic vein
dc.subjectPortal vein
dc.subjectPortal-vein pulsatility
dc.subjectWave-form
dc.subjectHepatic steatosis
dc.subjectGradient-echo
dc.subjectDual-echo
dc.subjectQuantification
dc.subjectInfiltration
dc.subjectHypertension
dc.subjectMacrosteatosis
dc.subjectDiagnosis
dc.subject.emtreeBlood flow velocity
dc.subject.emtreeDoppler flowmetry
dc.subject.emtreeEchography
dc.subject.emtreeFatty liver
dc.subject.emtreeFemale
dc.subject.emtreeHemodynamics
dc.subject.emtreeHepatic artery
dc.subject.emtreeHuman
dc.subject.emtreeLiver
dc.subject.emtreeLiver vein
dc.subject.emtreeMale
dc.subject.emtreeMiddle aged
dc.subject.emtreePortal vein
dc.subject.emtreeProcedures
dc.subject.emtreeProspective study
dc.subject.meshBlood flow velocity
dc.subject.meshFatty liver
dc.subject.meshFemale
dc.subject.meshHemodynamics
dc.subject.meshHepatic artery
dc.subject.meshHepatic veins
dc.subject.meshHumans
dc.subject.meshLiver
dc.subject.meshMale
dc.subject.meshMiddle aged
dc.subject.meshPortal vein
dc.subject.meshProspective studies
dc.subject.meshUltrasonography, doppler
dc.subject.scopusHepatic veins; Fibrosis; Liver cirrhosis
dc.subject.wosAcoustics
dc.subject.wosRadiology, nuclear medicine & medical imaging
dc.titleEffects of fat accumulation in the liver on hemodynamic variables assessed by Doppler ultrasonography
dc.typeArticle
dc.wos.quartileQ3 (Acoustics)
dc.wos.quartileQ4 (Radiology, nuclear medicine & medical imaging)
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Radyoloji Ana Bilim Dalı
local.contributor.departmentTıp Fakültesi/Biyoistatistik Ana Bilim Dalı
local.indexed.atPubMed
local.indexed.atScopus

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: