Publication:
Early-term outcomes for treatment of saphenous vein insufficiency with N-butyl cyanoacrylate: A novel, non-thermal, and non-tumescent percutaneous embolization technique

dc.contributor.authorTüydeş, Oktay
dc.contributor.authorYüksel, Ahmet
dc.contributor.authorŞenol, Sefa
dc.contributor.authorAkarsu, Serkan
dc.contributor.buuauthorTok, Mustafa
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentKalp Damar Cerrahisi Ana Bilim Dalı
dc.contributor.scopusid6506976035
dc.date.accessioned2022-10-27T08:55:31Z
dc.date.available2022-10-27T08:55:31Z
dc.date.issued2016-06
dc.description.abstractBackground: The purpose of this study was to present early-term outcomes of VariClose r Vein Sealing System, which is a novel, non-thermal, and non-tumescent percutaneous embolization technique for treatment of saphenous vein insufficiency. Methods: Between March 2014 and July 2015, 189 saphenous veins in 141 patients were treated with Variclose Vein Sealing System containing n-butyl cyanoacrylate. Pre-, intra-, post-procedural, and follow-up data of patients were collected and retrospectively reviewed. Results: Mean age of patients was 42.5 +/- 14.0 years, of which 53% were female. Technical success rate of intervention was 98.9%. Mean procedure time was 14.3 +/- 7.5 minutes. Eighty-nine percent of patients (n = 126/ 141) were available at mean follow-up time of 6.7 months. Mean Venous Clinical Severity Score was significantly improved from 8.3 +/- 2.2 at pre-procedure period to 3.3 +/- 1.8 at follow-up. No complete recanalization was observed, but 2 patients were presented with partial recanalization during follow-up. The complete occlusion rate was 98.4%. No serious adverse event related to procedure was observed. Conclusion: Variclose Vein Sealing System appears to be safe and effective in treatment of saphenous vein insufficiency. Further randomized studies with long-term outcomes are required for determining optimal treatment modality in patients with saphenous vein insufficiency.
dc.identifier.citationTok, M. vd. (2016). "Early-term outcomes for treatment of saphenous vein insufficiency with N-butyl cyanoacrylate: A novel, non-thermal, and non-tumescent percutaneous embolization technique". Heart Surgery Forum, 19(3), E118-E122.
dc.identifier.endpageE122
dc.identifier.issn1098-3511
dc.identifier.issn1522-6662
dc.identifier.issue3
dc.identifier.pubmed27355146
dc.identifier.scopus2-s2.0-84977652435
dc.identifier.startpageE118
dc.identifier.urihttps://doi.org/10.1532/hsf.1496
dc.identifier.urihttps://journal.hsforum.com/index.php/HSF/article/view/1496
dc.identifier.urihttp://hdl.handle.net/11452/29235
dc.identifier.volume19
dc.identifier.wos000384793300008
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherForum Multimedia Publishing
dc.relation.collaborationSanayi
dc.relation.journalHeart Surgery Forum
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCardiovascular system & cardiology
dc.subjectSurgery
dc.subjectThermal ablation
dc.subjectVaricose-veins
dc.subjectFollow-up
dc.subjectPolidocanol foam
dc.subjectGreat
dc.subjectSclerotherapy
dc.subjectMulticenter
dc.subjectTrial
dc.subjectAdhesive
dc.subjectReflux
dc.subject.emtreeAntibiotic agent
dc.subject.emtreeEnbucrilate
dc.subject.emtreeNonsteroid antiinflammatory agent
dc.subject.emtreeAdult
dc.subject.emtreeAged
dc.subject.emtreeArticle
dc.subject.emtreeArtificial embolization
dc.subject.emtreeClinical effectiveness
dc.subject.emtreeControlled study
dc.subject.emtreeDevice embolization
dc.subject.emtreeEcchymosis
dc.subject.emtreeFemale
dc.subject.emtreeFemoral vein
dc.subject.emtreeFollow up
dc.subject.emtreeHuman
dc.subject.emtreeIntraoperative period
dc.subject.emtreeMajor clinical study
dc.subject.emtreeMale
dc.subject.emtreeMean venous clinical severity score
dc.subject.emtreeOcclusion
dc.subject.emtreeOperation duration
dc.subject.emtreePercutaneous emblization technique
dc.subject.emtreePostoperative period
dc.subject.emtreePreoperative period
dc.subject.emtreePriority journal
dc.subject.emtreeRating scale
dc.subject.emtreeRecanalization
dc.subject.emtreeReintervention
dc.subject.emtreeRetrospective study
dc.subject.emtreeSafety
dc.subject.emtreeSaphenofemoral junction
dc.subject.emtreeSaphenous vein
dc.subject.emtreeSaphenous vein insufficiency
dc.subject.emtreeThrombophlebitis
dc.subject.emtreeTreatment duration
dc.subject.emtreeTreatment outcome
dc.subject.emtreeValsalva maneuver
dc.subject.emtreeVasospasm
dc.subject.emtreeVein diameter
dc.subject.emtreeVein insufficiency
dc.subject.emtreeArtificial embolization
dc.subject.emtreeMiddle aged
dc.subject.emtreeProcedures
dc.subject.emtreeVaricose veins
dc.subject.emtreeVenous Insufficiency
dc.subject.emtreeYoung adult
dc.subject.meshAdult
dc.subject.meshAged
dc.subject.meshEmbolization, therapeutic
dc.subject.meshFemale
dc.subject.meshHumans
dc.subject.meshMale
dc.subject.meshMiddle aged
dc.subject.meshRetrospective studies
dc.subject.meshSaphenous vein
dc.subject.meshVaricose veins
dc.subject.meshVenous insufficiency
dc.subject.meshYoung adult
dc.subject.scopusVaricosis; Saphenous Vein; Sclerotherapy
dc.subject.wosCardiac & cardiovascular systems
dc.subject.wosSurgery
dc.titleEarly-term outcomes for treatment of saphenous vein insufficiency with N-butyl cyanoacrylate: A novel, non-thermal, and non-tumescent percutaneous embolization technique
dc.typeArticle
dc.wos.quartileQ4
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Kalp Damar Cerrahisi Ana Bilim Dalı
local.indexed.atScopus
local.indexed.atWOS

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: