Publication:
Power loss analysis in amorphous ribbon materials

Placeholder

Date

Organizational Units

Authors

Derebaşı, Naim

Authors

Advisor

Language

Publisher:

Amer Inst Physics

Journal Title

Journal ISSN

Volume Title

Abstract

Localised specific power loss was determined for surface treated Metglas ((R)) 2605SC amorphous ribbons. The energy saving was maximum if the inhomogenity was reduced by polishing both surfaces. However, a further saving was noticed on the scratched samples. The optimum scratching interval for maximum energy saving was found to be 3 mm. The anomaly factor was also found to alter due to the domain wall spacing and loss measurement. The experimental findings showed that existing theory can reliably explain the power loss in amorphous ribbon.

Description

Bu çalışma, 22-26 Ağustos 2006 tarihlerinde İstanbul[Türkiye] düzenlenen 6. International Conference of the Balkan-Physical-Union Kongresi‘nde bildiri olarak sunulmuştur.

Source:

Keywords:

Keywords

Amorphous magnetic materials, Magnetization curves, Physics

Citation

Derebaşı, N. (2007). "Power loss analysis in amorphous ribbon materials". AIP Conference Proceedings, 899, 433-434.