Abstract

In this study, we have synthesized microparticle-embedded cryogel system for removal of 17 beta-estradiol (E2). Firstly, the poly(hydroxyethyl methacrylate-N-methacryloyl-L-tryptophan methyl ester) poly(HEMA-MATrp) microparticles were produced by emulsion polymerization. And then, poly(HEMA-MATrp) microparticles were embedded in poly(hydroxyethyl methacrylate) cryogel and [PHEMA/MATrp] cryogel system was prepared. [PHEMA/MATrp] cryogel system was used for the removal of E2. The characterization studies of the poly(HEMA-MATrp) microparticles and cryogel system were conducted by infrared spectroscopy, scanning electron microscopy, X-ray photoelectron spectroscopy, and swelling studies. The effects of initial concentration, temperature, and contact time on adsorption of E2 were investigated. Maximum adsorption capacity of PHEMA/MATrp cryogel was determined as 2.75 mg E2/g cryogel at 25 degrees C. The adsorption process obeyed both pseudo-second-order and intraparticle diffusion kinetic models. All the isotherm data can be fitted Langmuir isotherm model with high correlation coefficients for all studied temperatures. Thermodynamic parameters Delta H degrees = 654.9 J/mol, Delta S degrees = 85.90 J/K/mol, and Delta G degrees = -23.14 to -26.23 kJ/mol with the rise in temperature from 4 to 40 degrees C indicated that the adsorption process was endothermic and spontaneous. The E2 adsorption capacity did not change after five batch successive adsorption-desorption cycles, demonstrating the usefulness of the microparticle-embedded cryogel system in applications.

Description

Keywords

Engineering, Water resources, Endocrine disrupting, Cryogel, Estradiol, Removal, Particle-embedded, Waste-water, Imprinted polymers, Selective removal, Gelatin cryogels, Drinking-water, Contaminants, Adsorption, Performance, Capture, Surface, Adsorption, Aqueous solution, Endocrine disruptor, Isotherm, Polymerization, Reaction kinetics

Citation

Sarıkaya, A. G. vd. (2016). "Evaluation of the effectiveness of microparticle-embedded cryogel system in removal of 17β-estradiol from aqueous solution". Desalination and Water Treatment, 57(33), 15570-15579.

Collections

3

Views

0

Downloads

Search on Google Scholar