Effect of stress on localised flux directions in amorphous toroidal transducers

dc.contributor.authorMeydan, Turgut
dc.contributor.buuauthorDerebaşı, Naim
dc.contributor.departmentUludağ Üniversitesi/Fen-Edebiyat Fakültesi/Fizik Bölümü.tr_TR
dc.contributor.scopusid11540936300tr_TR
dc.date.accessioned2021-12-23T08:11:09Z
dc.date.available2021-12-23T08:11:09Z
dc.date.issued1997-04
dc.descriptionBu çalışma, 22-24 Temmuz 1996 tarihleri arasında Al I Cuza Üniversitesi, Iasi[Romanya]'de düzenlenen 1. European Magnetic Sensors and Actuators Conference'de bildiri olarak sunulmuştur.tr_TR
dc.description.abstractThe magnetic properties of amorphous materials vary with their chemical composition. Two types of amorphous ribbon, Metglas 2605SC and 2705M, were used to analyze the variation in flux direction with applied force at different flux density levels and frequencies. The induced voltages on the search coil wound parallel to the ribbon length was very significant in Metglas 2605SC, although it was found unaltered in Metglas 2705M tested at 1 kHz. Better working conditions were obtained on 2605SC sample while an unstable voltage was measured at high frequencies on 2705M. A higher variation in the induced voltage was obtained with applied stress from, as the stress dependence of the domain wall motion is crucial for the correct performance of the sensor. This investigation highlights the influence of bending stress in highly magnetostrictive and near zero magnetostrictive ribbons and concludes that the flux deviation in transverse direction may be influenced by applying stress onto the ribbons.en_US
dc.description.sponsorshipInst Tech Physen_US
dc.identifier.citationDerebaşı, N. ve Meydan, T. (1997). "Effect of stress on localised flux directions in amorphous toroidal transducers". Sensors and Actuators A-Physical, 59(1-3), 342-346.en_US
dc.identifier.endpage346tr_TR
dc.identifier.issn0924-4247
dc.identifier.issue1-3tr_TR
dc.identifier.scopus2-s2.0-0031119219tr_TR
dc.identifier.startpage342tr_TR
dc.identifier.urihttps://doi.org/10.1016/S0924-4247(97)80202-6
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0924424797802026
dc.identifier.urihttp://hdl.handle.net/11452/23485
dc.identifier.volume59tr_TR
dc.identifier.wosA1997XN00800066tr_TR
dc.indexed.scopusScopusen_US
dc.indexed.wosSCIEen_US
dc.indexed.wosCPCISen_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.collaborationYurt dışıtr_TR
dc.relation.journalSensors and Actuators A-Physicalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectEngineeringen_US
dc.subjectInstruments & instrumentationen_US
dc.subjectAmorphous ribbonen_US
dc.subjectFluxen_US
dc.subjectForceen_US
dc.subjectTransduceren_US
dc.subjectCoresen_US
dc.subjectAmorphous materialsen_US
dc.subjectElectric coilsen_US
dc.subjectMagnetic coresen_US
dc.subjectMagnetic domainsen_US
dc.subjectMagnetic propertiesen_US
dc.subjectMagnetostrictionen_US
dc.subjectSensorsen_US
dc.subjectStressesen_US
dc.subjectVoltage measurementen_US
dc.subjectAmorphous ribbonen_US
dc.subjectFlux density levelsen_US
dc.subjectStress dependenceen_US
dc.subjectTransducersen_US
dc.subject.scopusMagnetic Sensors; Domain Walls; Ribbonsen_US
dc.subject.wosEngineering, electrical & electronicen_US
dc.subject.wosInstruments & instrumentationen_US
dc.titleEffect of stress on localised flux directions in amorphous toroidal transducersen_US
dc.typeArticle