Publication:
Outcomes of cable fixation after vancouver type b1 periprosthetic femoral fractures

dc.contributor.authorYenigül, Ali Erkan
dc.contributor.authorErmutlu, Cenk
dc.contributor.authorÖnder, Cem
dc.contributor.authorAtıcı, Teoman
dc.contributor.authorDurak, Kemal
dc.contributor.buuauthorYENİGÜL, ALİ ERKAN
dc.contributor.buuauthorERMUTLU, CENK
dc.contributor.buuauthorÖNDER, CEM
dc.contributor.buuauthorATICI, TEOMAN
dc.contributor.buuauthorDURAK, KEMAL
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentOrtopedi ve Travmatoloji Ana Bilim Dalı
dc.contributor.orcid0000-0002-3396-3407
dc.contributor.orcid0000-0002-8289-8867
dc.contributor.researcheridAFH-1678-2022
dc.contributor.researcheridA-5095-2018
dc.contributor.researcheridAEQ-5464-2022
dc.contributor.researcheridJKS-7654-2023
dc.contributor.researcheridCOU-4147-2022
dc.date.accessioned2024-11-19T05:47:03Z
dc.date.available2024-11-19T05:47:03Z
dc.date.issued2023-11-01
dc.description.abstractBACKGROUND: In this study, it was aimed to evaluate the patients who underwent cable plate fixation due to a Vancouver-type B1 periprosthetic femur fracture and their clinical results.METHODS: Vancouver-type B1 patients who were operated on for periprosthetic fractures between 2014 and 2019 were investigated. Age, gender, body mass index (BMI), follow-up time, operation time, bleeding amount, non-union fracture, last surgery before fracture, the time between previous surgery and fracture, implant survival, patient survival, and complications were recorded. In addition, the postoperative clinical functions of these patients were compared. RESULTS: 23 patients who met the study criteria (Vancouver type B1 fracture) were identified. The mean age of the patients was 60 (49-76) years, the mean BMI was 26.3 (17.5-40.7), and the postoperative mean follow-up period was 14 (6-36) months. Considering the gender distribution, there were 5 (22%) men and 18 (78%) women. The mean time between the last surgery before the fracture and the fracture was 6 months (0-30). While the mean operation time was 95 min (60-180), the average amount of bleeding was 310 mL (150-600). Functional evaluations of patients: In total, five patients had decreased ambulatory abilities after surgery. Nonunion was observed in 2 patients during the follow-ups, and these patients underwent open surgery for treatment.CONCLUSION: Cable and locking plate applications are successful in Vancouver type B1 fractures, which are one of the most common forms of periprosthetic fractures. In this technique, the duration of the operation can be shortened under ideal conditions, and the need for blood and blood products is reduced as blood loss is reduced. If there is a complication, you still have the chance to treat it with the option of revision arthroplasty.
dc.identifier.doi10.14744/tjtes.2023.87425
dc.identifier.endpage1319
dc.identifier.issn1306-696X
dc.identifier.issue11
dc.identifier.startpage1314
dc.identifier.urihttps://doi.org/10.14744/tjtes.2023.87425
dc.identifier.urihttps://jag.journalagent.com/travma/pdfs/UTD_29_11_1314_1319.pdf
dc.identifier.urihttps://hdl.handle.net/11452/48039
dc.identifier.volume29
dc.identifier.wos001096720400015
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherTurkish Assoc Trauma Emergency Surgery
dc.relation.journalUlusal Travma ve Acil Cerrahi Dergisi-Turkish Journal of Trauma & Emergency Surgery
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectShaft fractures
dc.subjectPrinciples
dc.subjectMortality
dc.subjectCable and plate
dc.subjectOutcome
dc.subjectPeriprosthetic fractures
dc.subjectVancouver type b1
dc.subjectEmergency medicine
dc.titleOutcomes of cable fixation after vancouver type b1 periprosthetic femoral fractures
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Ortopedi ve Travmatoloji Ana Bilim Dalı
relation.isAuthorOfPublicationce6a66c8-e17a-4463-8a9e-dde91fa90215
relation.isAuthorOfPublication95736544-3429-4e55-b3ae-5ee564bd4060
relation.isAuthorOfPublicationeaf7c6a9-98a0-4b57-b201-77f2d8d7da73
relation.isAuthorOfPublicationac435e38-cf12-4daf-9c63-b2173adafd98
relation.isAuthorOfPublication260be1de-2df9-42bb-b5db-15dec3f094f8
relation.isAuthorOfPublication.latestForDiscoveryce6a66c8-e17a-4463-8a9e-dde91fa90215

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Yenigul_vd_2023.pdf
Size:
298.87 KB
Format:
Adobe Portable Document Format

Collections