Yayın: Towards robust picosec micromegas precise timing detectors
| dc.contributor.author | Lisowska, M. | |
| dc.contributor.author | Angelis, Y. | |
| dc.contributor.author | Aune, S. | |
| dc.contributor.author | Bortfeldt, J. | |
| dc.contributor.author | Brunbauer, F. | |
| dc.contributor.author | Chatzianagnostou, E. | |
| dc.contributor.author | Dehmelt, K. | |
| dc.contributor.author | Desforge, D. | |
| dc.contributor.author | Fanourakis, G. | |
| dc.contributor.author | Floethner, K. J. | |
| dc.contributor.author | Gallinaro, M. | |
| dc.contributor.author | Garcia, F. | |
| dc.contributor.author | Garg, P. | |
| dc.contributor.author | Giomataris, I. | |
| dc.contributor.author | Gnanvo, K. | |
| dc.contributor.author | Gustavsson, T. | |
| dc.contributor.author | Iguaz, F. J. | |
| dc.contributor.author | Janssens, D. | |
| dc.contributor.author | Kallitsopoulou, A. | |
| dc.contributor.author | Kovacic, M. | |
| dc.contributor.author | Legou, P. | |
| dc.contributor.author | Liu, J. | |
| dc.contributor.author | Lupberger, M. | |
| dc.contributor.author | Malace, S. | |
| dc.contributor.author | Maniatis, I. | |
| dc.contributor.author | Meng, Y. | |
| dc.contributor.author | Muller, H. | |
| dc.contributor.author | Oliveri, E. | |
| dc.contributor.author | Orlandini, G. | |
| dc.contributor.author | Papaevangelou, T. | |
| dc.contributor.author | Pomorski, M. | |
| dc.contributor.author | Ropelewski, L. | |
| dc.contributor.author | Sampsonidis, D. | |
| dc.contributor.author | Scharenberg, L. | |
| dc.contributor.author | Schneider, T. | |
| dc.contributor.author | Scorsone, E. | |
| dc.contributor.author | Sohl, L. | |
| dc.contributor.author | van Stenis, M. | |
| dc.contributor.author | Tsipolitis, Y. | |
| dc.contributor.author | Tzamarias, S. E. | |
| dc.contributor.author | Utrobicic, A. | |
| dc.contributor.author | Wang, X. | |
| dc.contributor.author | White, S. | |
| dc.contributor.author | Zhang, Z. | |
| dc.contributor.author | Zhou, Y. | |
| dc.contributor.buuauthor | Veenhof, Rob | |
| dc.contributor.department | Fen Edebiyat Fakültesi | |
| dc.contributor.department | Fizik Ana Bilim Dalı | |
| dc.contributor.orcid | 0000-0002-9746-4594 | |
| dc.contributor.orcid | 0000-0002-4023-7964 | |
| dc.contributor.orcid | 0000-0001-5143-4384 | |
| dc.contributor.orcid | 0000-0002-1155-9710 | |
| dc.contributor.orcid | 0000-0003-4494-2756 | |
| dc.contributor.orcid | 0000-0001-5754-199X | |
| dc.contributor.researcherid | JNS-2394-2023 | |
| dc.contributor.researcherid | C-5803-2016 | |
| dc.date.accessioned | 2024-11-29T06:00:43Z | |
| dc.date.available | 2024-11-29T06:00:43Z | |
| dc.date.issued | 2023-07-01 | |
| dc.description | Bu çalışma, 05-08 Eylül 2022 tarihleri arasında Catania[İtalya]’da düzenlenen 2nd International Workshop on Proton-Boron Fusion’da bildiri olarak sunulmuştur. | |
| dc.description.abstract | The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100 channel PICOSEC MM prototype with 10 x 10 cm(2) active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below sigma = 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects, i.e. integration of resistive MM and carbon-based photocathodes, while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below sigma = 20 ps for an individual pad obtained with the 10 x 10 cm(2) area resistive PICOSEC MM of 20 M Omega/square showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B4C) photocathode presented a time resolution below sigma = 35 ps, opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution. | |
| dc.identifier.doi | 10.1088/1748-0221/18/07/C07018 | |
| dc.identifier.issn | 1748-0221 | |
| dc.identifier.issue | 7 | |
| dc.identifier.scopus | 2-s2.0-85167622051 | |
| dc.identifier.uri | https://doi.org/10.1088/1748-0221/18/07/C07018 | |
| dc.identifier.uri | https://hdl.handle.net/11452/48683 | |
| dc.identifier.volume | 18 | |
| dc.identifier.wos | 001087757100004 | |
| dc.indexed.wos | WOS.SCI | |
| dc.indexed.wos | WOS.ISTP | |
| dc.language.iso | en | |
| dc.publisher | Iop Publishing Ltd | |
| dc.relation.journal | Journal Of Instrumentation | |
| dc.relation.publicationcategory | Konferans Öğesi – Uluslararası | |
| dc.subject | Resolution | |
| dc.subject | Cherenkov detectors | |
| dc.subject | Micropattern gaseous detectors (msgc, gem, thgem, rethgem, mhsp, micropic, micromegas, ingrid, etc) | |
| dc.subject | Timing detectors | |
| dc.subject | Science & technology | |
| dc.subject | Technology | |
| dc.subject | Instruments & instrumentation | |
| dc.title | Towards robust picosec micromegas precise timing detectors | |
| dc.type | conferenceObject | |
| dc.type.subtype | Proceedings Paper | |
| dspace.entity.type | Publication | |
| local.contributor.department | Fen Edebiyat Fakültesi/Fizik Ana Bilim Dalı | |
| local.indexed.at | WOS | |
| local.indexed.at | Scopus |
Dosyalar
Orijinal seri
1 - 1 / 1
