Publication:
Numerical investigation of an air cleaning device performance

dc.contributor.authorKılıç, Muhsin
dc.contributor.authorMutlu, Mustafa
dc.contributor.authorSaldamlı, İsmail Hakkı
dc.contributor.buuauthorKILIÇ, MUHSİN
dc.contributor.buuauthorMUTLU, MUSTAFA
dc.contributor.buuauthorSaldamlı, İsmail Hakkı
dc.contributor.departmentMühendislik Fakültesi
dc.contributor.departmentMakine Mühendisliği Bölümü
dc.contributor.orcid0000-0003-2113-4510
dc.contributor.orcid0000-0001-6816-8377
dc.contributor.researcheridO-2253-2015
dc.contributor.researcheridAAA-2005-2022
dc.contributor.researcheridDRD-6981-2022
dc.date.accessioned2024-10-07T12:44:54Z
dc.date.available2024-10-07T12:44:54Z
dc.date.issued2022-01-01
dc.description.abstractIn this study, the performance of a portable air cleaner, which is used to clean the air of a room with a person sitting in it, was investigated. The effects of different blowing angles and flow rates from the air supply vent on the device cleaning performance were investigated. In this context, air age and clean air delivery rate (CADR) parameters were calculated numerically. Randomly distributed particles in the room were tracked using the discrete phase model (DPM) and the relationship of pollutant concentrations with CADR and air age was examined. It has been seen that the blowing angle is an important parameter along with the flow rate. Moreover, it was concluded that the air age approach can be used to determine the performance of air cleaning devices. It has been found that the air cleaning device capture more than half of the particles in the environment, while the remaining particles are captured by other room surfaces.
dc.identifier.doi10.17341/gazimmfd.951560
dc.identifier.eissn1304-4915
dc.identifier.endpage2089
dc.identifier.issn1300-1884
dc.identifier.issue4
dc.identifier.startpage2077
dc.identifier.urihttps://doi.org/10.17341/gazimmfd.951560
dc.identifier.urihttps://dergipark.org.tr/tr/pub/gazimmfd/issue/68677/951560
dc.identifier.urihttps://hdl.handle.net/11452/45996
dc.identifier.volume37
dc.identifier.wos000767316300025
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherGazi Üniversitesi
dc.relation.journalGazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.relation.tubitak218M604
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectParticle-transport characteristics
dc.subjectIndoor environment
dc.subjectHeat-transfer
dc.subjectMoisture transport
dc.subjectThermal comfort
dc.subjectFlow
dc.subjectVentilation
dc.subjectExposure
dc.subjectImpact
dc.subjectCabin
dc.subjectClean air delivery rate (cadr)
dc.subjectAir age
dc.subjectAir cleaning device
dc.subjectAir purifier
dc.subjectCfd
dc.subjectScience & technology
dc.subjectTechnology
dc.subjectEngineering, multidisciplinary
dc.subjectEngineering
dc.titleNumerical investigation of an air cleaning device performance
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentMühendislik Fakültesi/Makine Mühendisliği Bölümü
local.contributor.departmentYenişehir Meslek Yüksekokulu
relation.isAuthorOfPublication56d98e3d-139a-4bf2-b105-8e1402865346
relation.isAuthorOfPublication7bde71fb-a52b-43a8-adbb-df86c8b51ce7
relation.isAuthorOfPublication.latestForDiscovery56d98e3d-139a-4bf2-b105-8e1402865346

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Kılıç_vd_2022.pdf
Size:
1.2 MB
Format:
Adobe Portable Document Format