Yayın:
Experimental performance investigation of a horizontal ground source compression refrigeration machine

dc.contributor.buuauthorCoşkun, Salih
dc.contributor.buuauthorPulat, Erhan
dc.contributor.buuauthorÜnlü, Kursat
dc.contributor.buuauthorYamankaradeniz, Recep
dc.contributor.departmentMühendislik Fakültesi
dc.contributor.departmentTeknik Bilimler Meslek Yüksekokulu
dc.contributor.departmentİklimlendirme ve Soğutma Programı
dc.contributor.departmentMakine Mühendisliği Bölümü
dc.contributor.orcid0000-0003-4070-4945
dc.contributor.scopusid26644674500
dc.contributor.scopusid23098080300
dc.contributor.scopusid25628645400
dc.contributor.scopusid6507733785
dc.date.accessioned2024-04-03T08:33:05Z
dc.date.available2024-04-03T08:33:05Z
dc.date.issued2008-01
dc.description.abstractIn this paper, the effect of various system parameters on horizontal ground source compression refrigeration machine (CRM) performance is studied experimentally in Bursa, Turkey. A ground heat exchanger (GHE) system connected to CRM in a test room in the air conditioning and refrigeration laboratory of Uludag University has been designed and constructed. This system was tested for space cooling in August and September 2004 and performance tests were performed during this period. Overall, system mainly consists of the GHE (GHE-water circuit) and CRM (CRM-refrigerant circuit). Refrigerant is R134a. Hourly variations of inlet and outlet water temperatures, extracted heat from test room, rejected heat to ground, compression ratio, total power consumption, and coefficient of performance (COP) values for both whole system and only CRM are obtained. Thermal properties of soil are also estimated by using experimental data and theory. Cooling load of test room and rejected heat to ground, and all COP values are also presented. Finally, heat rejection rate to ground with respect to leaving water temperature from GHE is given. The COP of the overall system changes between 2 and 2.5, also CRM COP values are in the range of 3 and 3.86.
dc.identifier.citationCoşkun, S. vd. (2008). "Experimental performance investigation of a horizontal ground source compression refrigeration machine". International Journal of Energy Research, 32(1), 44-56.
dc.identifier.doi10.1002/er.1350
dc.identifier.endpage56
dc.identifier.issn0363-907X
dc.identifier.issue1
dc.identifier.scopus2-s2.0-54949144010
dc.identifier.startpage44
dc.identifier.urihttps://doi.org/10.1002/er.1350
dc.identifier.urihttps://onlinelibrary.wiley.com/doi/abs/10.1002/er.1350
dc.identifier.urihttps://hdl.handle.net/11452/40948
dc.identifier.volume32
dc.identifier.wos000252519100005
dc.indexed.scopusScopus
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherWiley
dc.relation.journalInternational Journal of Energy Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEnergy & Fuels
dc.subjectNuclear Science & Technology
dc.subjectCompression refrigeration machine
dc.subjectCOP
dc.subjectExperimental
dc.subjectGround source
dc.subjectHorizontal heat exchanger
dc.subjectAir conditioning
dc.subjectCapillary tubes
dc.subjectCompression ratio (machinery)
dc.subjectCooling
dc.subjectData compression
dc.subjectExperiments
dc.subjectExtraction
dc.subjectHeat exchangers
dc.subjectRefrigerants
dc.subjectRefrigeration
dc.subjectSolar water heaters
dc.subjectTelecommunication networks
dc.subjectTesting
dc.subjectThermodynamic properties
dc.subjectCompression refrigeration machine
dc.subjectExperimental
dc.subjectGround source
dc.subjectHorizontal heat exchanger
dc.subjectSource heat-pump
dc.subjectMass-transfer model
dc.subjectAir-source
dc.subjectEnergysystem
dc.subjectTurkey
dc.subjectExchangers
dc.subjectSoil
dc.subjectSoil testing
dc.subject.scopusGeothermal Heat Pumps; Heat Exchangers; Boreholes
dc.subject.wosEnergy & fuels
dc.subject.wosNuclear science & technology
dc.titleExperimental performance investigation of a horizontal ground source compression refrigeration machine
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentTeknik Bilimler Meslek Yüksekokulu/İklimlendirme ve Soğutma Programı
local.contributor.departmentMühendislik Fakültesi/Makine Mühendisliği Bölümü
local.indexed.atWOS
local.indexed.atScopus

Dosyalar

Orijinal seri

Şimdi gösteriliyor 1 - 1 / 1
Küçük Resim
Ad:
Coşkun_vd_2008.pdf
Boyut:
365.97 KB
Format:
Adobe Portable Document Format

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Placeholder
Ad:
license.txt
Boyut:
1.71 KB
Format:
Item-specific license agreed upon to submission
Açıklama