dc.description.abstractIn this study, an experimental failure analysis is performed to calculate bearing strength of single bolted joints in laminated composites reinforced unidirectional glass fibers. The main goal of this study is to determine the failure behaviour of bolted composite joints under various preload moments as 0, 2.5 and 5 Nm. Furthermore, two different geometrical parameters that are the edge distance-to-hole diameter ratio (E/D) and plate width-to-hole diameter ratio (W/D) are investigated. For that reason, E/D and W/D ratios are selected from I to 5 and from 2 to 5, respectively. Besides, the effect of orientation angle of laminated plates is considered. Therefore, four different ply orientations are selected as [30 degrees](4), [45 degrees](4), [60 degrees](4) and [90 degrees](4). The experimental results show that the magnitudes of bearing strengths in single bolted composite joints are strictly influenced from increasing value of applied preload moments, changing of W/D and E/D ratios and also ply orientations.
dc.identifier.citationŞen, F. vd. (2010). "Failure response of single bolted composite joints under various preload". Indian Journal of Engineering and Materials Sciences, 17(1), 39-48.
dc.identifier.endpage48
dc.identifier.issn0971-4588
dc.identifier.issn0975-1017
dc.identifier.issue1
dc.identifier.scopus2-s2.0-78149461599
dc.identifier.startpage39
dc.identifier.urihttp://hdl.handle.net/11452/25467
dc.identifier.volume17
dc.identifier.wos000276992700006
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherNiscair
dc.relation.collaborationYurt içi
dc.relation.journalIndian Journal of Engineering and Materials Sciences
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBearing strength
dc.subjectFailure analysis
dc.subjectFiber reinforced composites
dc.subjectLaminated plates
dc.subjectBolted joints
dc.subjectMechanically fastened joints
dc.subjectStrength prediction
dc.subjectStress
dc.subjectEngineering
dc.subjectMaterials science
dc.subjectBolted joints
dc.subjectFailure analysis
dc.subjectLaminating
dc.subjectBearing strengths
dc.subjectBolted composite joint
dc.subjectFailure behaviour
dc.subjectFailure response
dc.subjectFiber reinforced composites
dc.subjectLaminated plate
dc.subjectOrientation angles
dc.subjectSingle-bolted joints
dc.subjectLaminated composites
dc.subject.scopusBolted Joints; Bolts; Interference Fit
dc.subject.wosEngineering, multidisciplinary
dc.subject.wosMaterials science, multidisciplinary
dc.titleFailure response of single bolted composite joints under various preload
dc.typeArticle
dc.wos.quartileQ4
dspace.entity.typePublication
local.contributor.departmentMühendislik Fakültesi/Makine Mühendisliği Bölümü
local.indexed.atScopus
local.indexed.atWOS

Dosyalar

Orijinal seri

Şimdi gösteriliyor 1 - 1 / 1
Küçük Resim
Ad:
Ozcan_vd_2010.pdf
Boyut:
656.71 KB
Format:
Adobe Portable Document Format

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Placeholder
Ad:
license.txt
Boyut:
1.71 KB
Format:
Item-specific license agreed upon to submission
Açıklama