Yayın:
Surface and build-up region dose characteristics for high energy photons

dc.contributor.authorBilge, Hatice
dc.contributor.authorKüçücük, Halil
dc.contributor.authorÇakır, Aydın
dc.contributor.buuauthorYöndem, Serpil
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentRadyasyon Onkolojisi Ana Bilim Dalı
dc.date.accessioned2024-10-21T06:05:25Z
dc.date.available2024-10-21T06:05:25Z
dc.date.issued2006-01-01
dc.description.abstractOBJECTIVESThe surface doses of high energy photon beams show variability depending on the design of the treatment machine. Especially while using bolus that has a direct effect on surface and build-up region doses, defining correctly in the treatment planning system used for patient treatment is very important. It needs to be measured for each radiation beam used. In this study, the dose change of high energy beams surface and build-up region that were used in I.U. Oncology Institute according to the field size and the skin source distance were investigated.METHODSCo-60 teletherapy equipment, Orion 4 (MV), Saturn 42 (6-15 MV) high energy x-rays were used. Measurements were made for different field sizes and source skin distances by using Marcus-type parallel plate ion chamber at water equivalent solid phantom, at surface and build-up region. Measured surface and build-up doses were installed to CMS XiO treatment planning system.RESULTSAs a result of this study, the surface dose increased linearly as the field size increased and the maximum dose point was moved toward the surface by 1-2 mm as predicted. Surface doses for a 10x10 cm field size are 24.3%, 17.4%, 12.6% and 10.2% respectively for Co-60, 4MV, 6MV and 15MV. With the increase in skin source distance, a decrease in surface doses is observed.CONCLUSIONThe use of correct information is achieved by downloading surface doses measured for different field sizes to the treatment planning system.
dc.identifier.endpage173
dc.identifier.issn1300-7467
dc.identifier.issue4
dc.identifier.startpage168
dc.identifier.urihttps://hdl.handle.net/11452/46749
dc.identifier.volume21
dc.identifier.wos000439249500002
dc.indexed.wosWOS.ESCI
dc.language.isoen
dc.publisherKare Publ
dc.relation.journalTurk Onkoloji Dergisi-turkish Journal Of Oncology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectBuild-up region
dc.subjectHigh energy photons
dc.subjectSurface dose
dc.subjectRadiotherapy dosage
dc.subjectScience & technology
dc.subjectLife sciences & biomedicine
dc.subjectOncology
dc.titleSurface and build-up region dose characteristics for high energy photons
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Radyasyon Onkolojisi Ana Bilim Dalı
local.indexed.atWOS

Dosyalar