Yayın:
Detection of multiple power quality disturbance events for micro-smart grids with hydrogen fuel cell

dc.contributor.authorAkkaya, Sıtkı
dc.contributor.authorGüçyetmez, Mehmet
dc.contributor.buuauthorHAYBER, ŞEKİP ESAT
dc.contributor.buuauthorUYAR, MURAT
dc.contributor.departmentMühendislik Fakültesi
dc.contributor.departmentElektrik ve Elektronik Mühendisliği Ana Bilim Dalı
dc.contributor.orcid0000-0003-0062-3817
dc.contributor.researcheridJCT-7723-2023
dc.contributor.researcheridV-2823-2018
dc.date.accessioned2025-11-06T16:33:34Z
dc.date.issued2025-07-03
dc.description.abstractDue to some factors such as a greater need for energy and diversification of energy sources, micro-smart grids (MSGs) with hydrogen energy (HE) based fuel cells (FCs) are becoming increasingly widespread, and these systems have effects on the power grid in terms of power quality. Single and multiple power quality disturbances (PQDs) and their levels originating from the interaction and effects of peripheral units with FC-MSG should be detected using signal processing methods. The study aims to determine the error metrics of these disturbances when multiple disturbances occur in the power system with FC-MG, to analyze whether they are FC-induced, with which signal processing methods they can be analyzed, whether a filter is needed, and to determine the effectiveness of signal processing methods for different PQD situations. In the signal processing stage, wavelet synchro-squeezed transform (WSST) is used to analyze and visualize the PQD signals. Additionally, the time-frequency representation derived by WSST is compared with that derived from the continuous wavelet transform (CWT) to evaluate its ability to visually decompose the time-varying frequency components of PQD signals. Statistical error metrics, the root mean square error (RMSE), mean square error (MSE), and correlation (Corr) values, are used to evaluate the accuracy of the results. Specifically, RMSE, MSE, and Corr improved by 7.38%, 1.04%, and 47.33%, respectively, for the four mixed disturbance signals. The results show that the proposed visual analysis tool effectively detects multiple PQD signals. Determining the type and time of the disturbance performed in this study ensures timely and correct switching of relays in FC-MSG systems. Thus, MSG and FCs are less impacted by disturbance.
dc.description.sponsorshipSivas University of Science and Technology, Department of Electrical-Electronics Engineering, Smart Grids Laboratory
dc.identifier.doi10.1016/j.ijhydene.2025.02.046
dc.identifier.endpage563
dc.identifier.issn0360-3199
dc.identifier.scopus2-s2.0-85217470830
dc.identifier.startpage548
dc.identifier.urihttps://doi.org/10.1016/j.ijhydene.2025.02.046
dc.identifier.urihttps://hdl.handle.net/11452/56521
dc.identifier.volume144
dc.identifier.wos001518660400001
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherPergamon-elsevier science ltd
dc.relation.journalInternational journal of hydrogen energy
dc.subjectEnergy
dc.subjectClassıfıcatıon
dc.subjectTransıtıon
dc.subjectStabılıty
dc.subjectNetworks
dc.subjectSystems
dc.subjectSolar
dc.subjectFuel cell
dc.subjectHydrogen energy
dc.subjectMicro-smart grids
dc.subjectPower quality
dc.subjectMultiple disturbances
dc.subjectScience & Technology
dc.subjectPhysical Sciences
dc.subjectTechnology
dc.subjectChemistry, Physical
dc.subjectElectrochemistry
dc.subjectEnergy & Fuels
dc.subjectChemistry
dc.subjectElectrochemistry
dc.titleDetection of multiple power quality disturbance events for micro-smart grids with hydrogen fuel cell
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentMühendislik Fakültesi/Elektrik ve Elektronik Mühendisliği Ana Bilim Dalı
local.indexed.atWOS
local.indexed.atScopus
relation.isAuthorOfPublicationdff5e1ef-6b19-4f8e-9a7d-91e1f44a6773
relation.isAuthorOfPublication2b7e6090-8c83-4b82-a0c9-f479024ebdc4
relation.isAuthorOfPublication.latestForDiscoverydff5e1ef-6b19-4f8e-9a7d-91e1f44a6773

Dosyalar

Orijinal seri

Şimdi gösteriliyor 1 - 1 / 1
Küçük Resim
Ad:
Hayber_vd_2025.pdf
Boyut:
12.49 MB
Format:
Adobe Portable Document Format