Yayın:
A practical method for in-situ thickness determination using energy distribution of beta particles

dc.contributor.authorYalçın, Sezai
dc.contributor.authorGündoğdu, Özcan
dc.contributor.authorBradley, David A.
dc.contributor.buuauthorGürler, Orhan
dc.contributor.departmentFen Edebiyat Fakültesi
dc.contributor.departmentFizik Bölümü
dc.contributor.researcheridAAH-1837-2021
dc.contributor.scopusid14019444500
dc.date.accessioned2022-04-13T12:44:56Z
dc.date.available2022-04-13T12:44:56Z
dc.date.issued2012-01
dc.description.abstractThis paper discusses a method to determine the thickness of an absorber using the energy distribution of beta particles. An empirical relationship was obtained between the absorber thickness and the energy distribution of beta particles transmitted through. The thickness of a polyethylene radioactive source cover was determined by exploiting this relationship, which has largely been left unexploited allowing us to determine the in-situ cover thickness of beta sources in a fast, cheap and non-destructive way.
dc.identifier.citationYalçın, S. vd. (2012). "A practical method for in-situ thickness determination using energy distribution of beta particles". Applied Radiation and Isotopes, 70(1), 128-132.
dc.identifier.doi10.1016/j.apradiso.2011.08.001
dc.identifier.endpage132
dc.identifier.issn0969-8043
dc.identifier.issue1
dc.identifier.pubmed21868242
dc.identifier.scopus2-s2.0-84860412873
dc.identifier.startpage128
dc.identifier.urihttps://doi.org/10.1016/j.apradiso.2011.08.001
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0969804311004064
dc.identifier.urihttp://hdl.handle.net/11452/25759
dc.identifier.volume70
dc.identifier.wos000297901400020
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherPergamon-Elsevier
dc.relation.collaborationYurt içi
dc.relation.collaborationYurt dışı
dc.relation.journalApplied Radiation and Isotopes
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectChemistry
dc.subjectNuclear science & technology
dc.subjectRadiology, nuclear medicine & medical imaging
dc.subjectBeta particle
dc.subjectEnergy distribution
dc.subjectThickness
dc.subjectMass-attenuation coefficients
dc.subjectMonoenergetic electrons
dc.subjectDetector
dc.subjectIon beams
dc.subjectAbsorber thickness
dc.subjectBeta particles
dc.subjectCover thickness
dc.subjectEnergy distributions
dc.subjectIn-situ
dc.subjectNon destructive
dc.subjectPractical method
dc.subjectRadioactive sources
dc.subjectThickness determination
dc.subjectElectric power distribution
dc.subject.emtreePolyethylene
dc.subject.emtreeStrontium 90
dc.subject.emtreeYttrium 90
dc.subject.emtreeArticle
dc.subject.emtreeControlled study
dc.subject.emtreeDosimetry
dc.subject.emtreeElectron
dc.subject.emtreeIsotope analysis
dc.subject.emtreeNeutron radiation
dc.subject.emtreePriority journal
dc.subject.emtreeRadiation detection
dc.subject.emtreeRadiation dose distribution
dc.subject.emtreeRadiation measurement
dc.subject.emtreeRadioactivity
dc.subject.emtreeSpectral sensitivity
dc.subject.emtreeThickness
dc.subject.meshBeta particles
dc.subject.meshDensitometry
dc.subject.meshEnergy transfer
dc.subject.meshEquipment design
dc.subject.meshEquipment failure analysis
dc.subject.meshHumans
dc.subject.meshRadiometry
dc.subject.meshSensitivity and specificity
dc.subject.meshSkin physiological phenomena
dc.subject.scopusPlane Source; Beta Particles; Proportional Counters
dc.subject.wosChemistry, inorganic & nuclear
dc.subject.wosNuclear science & technology
dc.subject.wosRadiology, nuclear medicine & medical imaging
dc.titleA practical method for in-situ thickness determination using energy distribution of beta particles
dc.typeArticle
dc.wos.quartileQ3
dspace.entity.typePublication
local.contributor.departmentFen Edebiyat Fakültesi/Fizik Bölümü
local.indexed.atScopus
local.indexed.atWOS

Dosyalar

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Placeholder
Ad:
license.txt
Boyut:
1.71 KB
Format:
Item-specific license agreed upon to submission
Açıklama