Yayın:
The second dorsal metacarpal artery flap with double pivot points

dc.contributor.buuauthorKaracalar, Ahmet
dc.contributor.buuauthorAkın, Selçuk
dc.contributor.buuauthorÖzcan, Mesut
dc.contributor.departmentUludaǧ Üniversitesi
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentPlastik ve Rekonstruktif Cerrahi Ana Bilim Dalı
dc.contributor.scopusid7004405636
dc.contributor.scopusid7005263372
dc.contributor.scopusid7102067678
dc.date.accessioned2021-09-03T08:22:00Z
dc.date.available2021-09-03T08:22:00Z
dc.date.issued1996
dc.description.abstractA flap with double pivot points based on the second dorsal metacarpal artery was used in 13 cases with no complete failures, In 2 cases, the branches of the radial nerve were included in the flap. In 1 case, the flap was used as a tenocutaneous flap with a segment of the extensor indicis proprius tendon. To obtain a flap with double pivot points, the dissection of the vascular pedicle of a distally based second dorsal metacarpal flap is continued proximally under the second dorsal metacarpal artery up to its origin, In this flap the main pivot point coincides with the origin of the SDR IA and the second pivot point with the entry point of the recurrent cutaneous branch into the flap, We found this flap to be very versatile, reliable, and quite easy and quick to raise, We report our experience with this flap as a very useful addition to reconstructive procedures, especially for thumb defects.
dc.identifier.citationKaracalar, A. (1996). "The second dorsal metacarpal artery flap with double pivot points". British Journal of Plastic Surgery, 49(2), 97-102.
dc.identifier.doi10.1016/S0007-1226(96)90081-8
dc.identifier.endpage102
dc.identifier.issn0007-1226
dc.identifier.issue2
dc.identifier.pubmed8733348
dc.identifier.scopus2-s2.0-0030009185
dc.identifier.startpage97
dc.identifier.urihttps://doi.org/10.1016/S0007-1226(96)90081-8
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0007122696900818
dc.identifier.urihttp://hdl.handle.net/11452/21664
dc.identifier.volume49
dc.identifier.wosA1996UE88700005
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherChurchill Livingstone
dc.relation.journalBritish Journal of Plastic Surgery
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectSurgery
dc.subjectIsland flap
dc.subjectTransposition
dc.subjectDefects
dc.subjectThumb
dc.subjectHand
dc.subject.emtreeAdolescent
dc.subject.emtreeAdult
dc.subject.emtreeAged
dc.subject.emtreeArtery
dc.subject.emtreeClinical article
dc.subject.emtreeFemale
dc.subject.emtreeHand
dc.subject.emtreeHand surgery
dc.subject.emtreeHuman
dc.subject.emtreeMale
dc.subject.emtreeMetacarpal artery
dc.subject.emtreeNeurovascular island flap
dc.subject.emtreePriority journal
dc.subject.emtreeRadial nerve
dc.subject.emtreeTendon
dc.subject.emtreeThumb reconstruction
dc.subject.scopusSurgical Flaps; Flaps (Control Surfaces); Metacarpal Bones
dc.subject.wosSurgery
dc.titleThe second dorsal metacarpal artery flap with double pivot points
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentUludaǧ Üniversitesi/Tıp Fakültesi/Plastik ve Rekonstruktif Cerrahi Ana Bilim Dalı
local.indexed.atScopus
local.indexed.atWOS

Dosyalar

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Placeholder
Ad:
license.txt
Boyut:
1.71 KB
Format:
Item-specific license agreed upon to submission
Açıklama