Publication:
Cold vapour generation and on-line trapping of cadmium species on quartz surface prior to detection by atomic absorption spectrometry

dc.contributor.authorKorkmaz, Deniz
dc.contributor.authorAydın, Fırat
dc.contributor.authorAtaman, O. Yavuz
dc.contributor.buuauthorDemir, Cevdet
dc.contributor.departmentFen Edebiyat Fakültesi
dc.contributor.departmentKimya Bölümü
dc.contributor.orcid0000-0003-1508-0181
dc.contributor.orcid0000-0002-9381-0410
dc.contributor.researcheridABA-2005-2020
dc.date.accessioned2021-07-07T10:53:13Z
dc.date.available2021-07-07T10:53:13Z
dc.date.issued2005
dc.description.abstractA quartz trap for on-line preconcentration of Cd species was designed. The cold vapour generation technique was used for the generation of Cd species. The trapping medium was formed by external heating of the inlet arm of a quartz T-tube. The generated analyte species were trapped on a quartz surface heated to the collection temperature, 350 degreesC, and the collected species were revolatilized when the trap was heated further to revolatilization temperature, 1000 degreesC, and hydrogen gas was introduced in the trapping medium. Two-level fractional factorial design and central composite design were used to optimize generation conditions in the flow injection mode. The results of the fractional factorial design demonstrated that the factors and their interactions were statistically significant. Three factors, length of reaction coil, carrier HCl concentration and NaBH4 concentration, were considered to be the most significant parameters in the optimization and their optimum values were found to be 30 cm, 0.3 M and 3% (m/v), respectively. Sea-water (BCR), tomato leaves (NIST 1573a) and oyster tissue ( NIST 1566b) standard reference materials were analyzed to assess the accuracy of the proposed method. For a collection period of 3.0 min, i.e., 6.0 ml sample volume, the 3sigma limit of detection was 1.8 pg ml(-1); the enhancement factor for LOD was found to be 90 as compared with FI-HGAAS. The sample throughput rate was 12 h(-1).
dc.identifier.citationKorkmaz, D. vd. (2005). "Cold vapour generation and on-line trapping of cadmium species on quartz surface prior to detection by atomic absorption spectrometry". Journal of Analytical Atomic Spectrometry, 20(1), 46-52.
dc.identifier.endpage52
dc.identifier.issn0267-9477
dc.identifier.issue1
dc.identifier.scopus2-s2.0-12344262273
dc.identifier.startpage46
dc.identifier.urihttps://doi.org/10.1039/b410584b
dc.identifier.urihttps://pubs.rsc.org/en/content/articlelanding/2005/JA/B410584B
dc.identifier.urihttp://hdl.handle.net/11452/21158
dc.identifier.volume20
dc.identifier.wos000225852000008
dc.indexed.scopusScopus
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherRoyal Soc Chemistry
dc.relation.collaborationYurt içi
dc.relation.journalJournal of Analytical Atomic Spectrometry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectHydride generation
dc.subjectOptimization
dc.subjectMultiple microflame
dc.subjectBorane complexes
dc.subjectFactorial design
dc.subjectAqueous-media
dc.subjectFlame aas
dc.subjectPreconcentration
dc.subjectAtomization
dc.subjectMechanisms
dc.subjectChemistry
dc.subjectSpectroscopy
dc.subject.wosChemistry, analytical
dc.subject.wosSpectroscopy
dc.titleCold vapour generation and on-line trapping of cadmium species on quartz surface prior to detection by atomic absorption spectrometry
dc.typeArticle
dc.wos.quartileQ1
dspace.entity.typePublication
local.contributor.departmentFen Edebiyat Fakültesi/Kimya Bölümü
local.indexed.atWOS
local.indexed.atScopus

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: