dc.description.abstractDuring the seismic performance assessment of existing buildings, staircases are generally not taken into account as structural members but as dead load. Staircases, as secondary structural members, not only serve for connecting successive floors but also provide considerable amount of strength and stiffness to the building which can modify its seismic behaviour considerably. In this parametric study, the influence of staircases on the seismic response of substandard RC frame buildings which differ in number of storey and span, presence of staircase and its position has been examined. Modal Analyses and bidirectional Non-Linear Time History Analyses (NLTHA) were conducted to compare several engineering demand parameters (EDPs) such as inter-storey drift ratio (ISDR), floor accelerations, modal properties, member shear forces and plastic hinge distribution. Additionally, short column effect, variation in shear forces of columns that are attached to the staircase slab, failure and deformation in staircase models have also been investigated. As the staircase was considered in the analytical model, a different damage pattern can be developed especially in the structural components close to staircase.
dc.identifier.doi10.12989/eas.2019.17.3.283
dc.identifier.endpage295
dc.identifier.issn2092-7614
dc.identifier.issue3
dc.identifier.scopus2-s2.0-85108153641
dc.identifier.startpage283
dc.identifier.urihttps://doi.org/10.12989/eas.2019.17.3.283
dc.identifier.urihttp://koreascience.or.kr/article/JAKO201927064637971.page
dc.identifier.urihttps://hdl.handle.net/11452/43112
dc.identifier.volume17
dc.identifier.wos000496270800004
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherTechno-Press
dc.relation.journalEarthquakes and Structures
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectDamage
dc.subjectSubstandard
dc.subjectRc frame
dc.subjectStaircase
dc.subjectShort column
dc.subjectSeismic
dc.subjectEngineering
dc.titleSeismic response of substandard rc frame buildings in consideration of staircases
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentMühendislik Fakültesi/İnşaat Mühendisliği Bölümü
local.indexed.atWOS
local.indexed.atScopus

Dosyalar