Yayın:
Signal fluctuation in neutron-irradiated silicon Avalanche Photodiodes

dc.contributor.buuauthorPiliçer, Ercan
dc.contributor.buuauthorTapan, İlhan
dc.contributor.departmentFen Edebiyat Fakültesi
dc.contributor.departmentFizik Bölümü
dc.contributor.scopusid15843878300
dc.contributor.scopusid8905787000
dc.date.accessioned2024-03-11T05:59:28Z
dc.date.available2024-03-11T05:59:28Z
dc.date.issued2007-04-01
dc.descriptionBu çalışma, 09-13, Eylül 2005 tarihlerinde Liverpool[İngiltere]’de düzenlenen 7. International Conference on Position-Senstive Detectors Kongresi‘nde bildiri olarak sunulmuştur.
dc.description.abstractLight from PbWO4 crystals in the barrel part of the CMS electromagnetic calorimeter will be detected by Avalanche Photodiodes (APDs). The crystal-APD system has to operate reliably in a high radiation environment. In the present paper, APD signal variation with wavelength and gain fluctuations for PbW04 scintillation light was investigated as a function of the neutron fluence. Calculations were made with a single-particle Monte Carlo simulation technique. The results show that the neutron fluence has an influence on the APD signal during 10 years CMS operation.
dc.description.sponsorshipEngn & Phys Sci Res Council
dc.description.sponsorshipParticle Phys & Astron Res Council
dc.description.sponsorshipCoucil Cent Lab Res Council; Inst Phys High Energy Phys Grp
dc.description.sponsorshipInst Phys Nucl Phys Grp
dc.identifier.citationPiliçer, E. ve Tapan, İ. (2007). ''Signal fluctuation in neutron-irradiated silicon Avalanche Photodiodes''. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 573(1-2), 291-293.
dc.identifier.doi10.1016/j.nima.2006.10.263
dc.identifier.endpage293
dc.identifier.issn0168-9002
dc.identifier.issue1-2
dc.identifier.scopus2-s2.0-33847618451
dc.identifier.startpage291
dc.identifier.urihttps://reader.elsevier.com/reader/sd/pii/S016890020602208X
dc.identifier.urihttps://hdl.handle.net/11452/40317
dc.identifier.volume573
dc.identifier.wos000245624200078
dc.indexed.wosCPCIS
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherElsevier
dc.relation.journalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCalorimeters
dc.subjectSilicon
dc.subjectCrystals
dc.subjectRadiation damage
dc.subjectGain measurement
dc.subjectNeutron irradiation
dc.subjectLead compounds
dc.subjectMonte Carlo methods
dc.subjectLead tungstate crystals
dc.subjectSignal fluctuation
dc.subjectAvalanche photodiodes
dc.subjectInstruments & instrumentation
dc.subjectNuclear science & technology
dc.subjectPhysics
dc.subjectAvalanche photodiodes
dc.subjectSignal fluctuation
dc.subjectLead-tungstate crystal
dc.subjectRadiation damage
dc.subjectMonte Carlo simulation
dc.subjectCms electromagnetic calorimeter
dc.subjectRadiation-damage
dc.subjectDetectors
dc.subjectCrystals
dc.subject.scopusAvalanche Photodiodes; Dark Currents; Calorimeters
dc.subject.wosInstruments & instrumentation
dc.subject.wosPhysics, particles & fields
dc.subject.wosNuclear science & technology
dc.subject.wosPhysics, nuclear
dc.titleSignal fluctuation in neutron-irradiated silicon Avalanche Photodiodes
dc.typeconferenceObject
dc.type.subtypeProceedings Paper
dc.wos.quartileQ2 (Instruments & instrumentation)
dc.wos.quartileQ1 (Nuclear science & technology)
dc.wos.quartileQ3 (Spectroscopy)
dspace.entity.typePublication
local.contributor.departmentFen Edebiyat Fakültesi/Fizik Bölümü
local.indexed.atWOS
local.indexed.atScopus

Dosyalar

Orijinal seri

Şimdi gösteriliyor 1 - 1 / 1
Küçük Resim
Ad:
Piliçer_ve_Tapan_2007
Boyut:
172.04 KB
Format:
Adobe Portable Document Format

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Placeholder
Ad:
license.txt
Boyut:
1.71 KB
Format:
Item-specific license agreed upon to submission
Açıklama