Publication:
Evaluation of glutaraldehyde coagulation test and colostrum brix refractometer compared with snap foal igg test in neonatal foals

dc.contributor.authorBabaeski, Serdar
dc.contributor.buuauthorKasap, Sevim
dc.contributor.buuauthorKENNERMAN, ENGİN
dc.contributor.buuauthorKASAP, SEVİM
dc.contributor.buuauthorKennerman, Engin
dc.contributor.buuauthorORMAN, ABDÜLKADİR
dc.contributor.buuauthorOrman, Abdulkadir
dc.contributor.buuauthorTEMİZEL, ETHEM MUTLU
dc.contributor.buuauthorYıldırım, Kübra Nur
dc.contributor.buuauthorYILDIRIM, KÜBRA NUR
dc.contributor.departmentVeteriner Fakültesi
dc.contributor.orcid0000-0001-9138-4422
dc.contributor.researcheridAAG-9134-2021
dc.date.accessioned2024-09-11T06:19:08Z
dc.date.available2024-09-11T06:19:08Z
dc.date.issued2023-10-01
dc.description.abstractBackground: Prompt diagnosis of passive transfer failure in the neonatal period is important for early treatment.Objectives: To compare the diagnostic performance of serum glutaraldehyde coagulation test (GCT) and colostrum BRIX% for failure to transfer passive immunity (FTPI) diagnosis with the results of SNAP foal test and to evaluate the results of serum GCT and colostrum BRIX% measurements in foals with diarrhoea in the 0-1 month period.Study design: In vitro experiments.Methods: Excess serum and colostrum (n: 298) from samples collected from newborn foals and their dams for clinical purposes were used. Foals were classified as FTPI positive (IgG < 8 g/L) or negative (IgG >= 8 g/L) using the SNAP foal test. We compared the sensitivity and specificity of serum GCT and colostrum BRIX % for diagnosing FTPI in all foals and in the sub-group of foals which developed diarrhoea within the first month of life was noted. The relationships between the results of the serum GCT and colostrum BRIX% and diarrhoea in foals with and without FTPI were evaluated.Results: Serum GCT and colostrum BRIX % were statistically significantly different (p < 0.05) between the foals without FTPI and with FTPI classified according to the SNAP test. Using a cut-off value for serum GCT of >10, sensitivity was 100% (95% CI 92.9%-100%) and specificity 100% (98.3%-100%) while with a cut-off value of <= 24, with colostrum BRIX% of <= 24 sensitivity was 92% (80.9%-97.8%), and specificity was 98% (95.3-99.3). In the sub-group of foals without FTPI using a colostrum BRIX% cut-off value of <= 26 the sensitivity for prediction of diarrhoea in the 0-1 month period was only 72.4% (52.8-87.3, p < 0.001) with specificity 54.3% (47.6-61.1) but the test performance was not robust (ROC AUC 0.61).Main limitations: The number of repeated measurements in the evaluation of serum GCT, and colostrum BRIX% was low. More clinical problems could be examined.Conclusions: The serum GCT, and colostrum BRIX%, both economical and practical to use in the field, gave results comparable with the SNAP foal IgG test. The ability to accurately predict diarrhoea in the first month of life with these tests was limited.
dc.description.sponsorshipWe thank the veterinarians and other staff of Karacabey Stud and Breeding Station of the Turkish Jockey Club who contributed.
dc.identifier.doi10.1111/evj.14011
dc.identifier.endpage1082
dc.identifier.issn0425-1644
dc.identifier.issue5
dc.identifier.startpage1077
dc.identifier.urihttps://doi.org/10.1111/evj.14011
dc.identifier.urihttps://hdl.handle.net/11452/44530
dc.identifier.volume56
dc.identifier.wos001075559700001
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherWiley
dc.relation.journalEquine Veterinary Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectImmunoglobulin-g concentration
dc.subjectGlutamyl-transferase activity
dc.subjectSulfate turbidity test
dc.subjectPassive transfer
dc.subjectSerum igg
dc.subjectRadial immunodiffusion
dc.subjectProtein-concentration
dc.subjectGoat kids
dc.subjectFailure
dc.subjectImmunity
dc.subjectBrix %
dc.subjectColostrum
dc.subjectFoal
dc.subjectGct
dc.subjectHorse
dc.subjectNeonatal
dc.subjectPassive immunity
dc.subjectSerum
dc.subjectSnap test
dc.subjectScience & technology
dc.subjectLife sciences & biomedicine
dc.subjectVeterinary sciences
dc.titleEvaluation of glutaraldehyde coagulation test and colostrum brix refractometer compared with snap foal igg test in neonatal foals
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentVeteriner Fakültesi
relation.isAuthorOfPublicatione1680f7b-14c0-45b4-bc79-b42a5b330709
relation.isAuthorOfPublicationf15e9220-38cc-4191-85a3-16486349833d
relation.isAuthorOfPublication32cdabad-4bba-40b7-b2b6-b36bb228ea66
relation.isAuthorOfPublication7bd8a440-0ce5-4484-91d2-562695d12be1
relation.isAuthorOfPublication.latestForDiscoverye1680f7b-14c0-45b4-bc79-b42a5b330709

Files

Collections