dc.descriptionBu çalışma, 04-08 Haziran 2012 tarihleri arasında Santa Fe[New Mexico]’da düzenlenen 15. International Conference on Calorimetry in High Energy Physics (CALOR)’da bildiri olarak sunulmuştur.
dc.description.abstractAccording to the Turkish Accelerator Center (TAC) project, a tau-charm factory is proposed based on colliding a 1 GeV electron beam against a 3.5 GeV positron beam. The Particle Factory (TAC-PF) detector will be constructed for the detection of the producing particles from this collision. PbWO4 and CsI(Tl) crystals are considered for the construction of the electromagnetic calorimeter. The photons generated from incident particles in the crystal material are detected by Avalanche photodiodes (APD) or PIN photodiodes placed at the end of the crystal. In this work, the contribution to the calorimetric energy resolution from both the shower fluctuations in the crystal and photoelectron statistics in the detectors have been simulated for PbWO4-APD and PbWO4-PIN combinations.
dc.description.sponsorshipDevlet Planlama Teşkilatı (DPT) 2006K-120470
dc.identifier.citationTapan, İ. ve Koçak, F. (2012). "Simulation work on calorimetric energy resolution for the TAC-PF detector". Journal of Physics Conference Series, XVth International Conference on Calorimetry in High Energy Physics (Calor2012), 404(1), 1-5.
dc.identifier.doi10.1088/1742-6596/404/1/012053
dc.identifier.endpage5
dc.identifier.issn1742-6588
dc.identifier.issn1742-6596
dc.identifier.issue1
dc.identifier.scopus2-s2.0-84873627723
dc.identifier.startpage1
dc.identifier.urihttps://doi.org/10.1088/1742-6596/404/1/012053
dc.identifier.urihttps://iopscience.iop.org/article/10.1088/1742-6596/404/1/012053
dc.identifier.urihttp://hdl.handle.net/11452/25808
dc.identifier.volume404
dc.identifier.wos000314704100053
dc.indexed.wosCPCIS
dc.language.isoen
dc.publisherIop Publishing
dc.relation.journalJournal of Physics Conference Series, XVth International Conference on Calorimetry in High Energy Physics (Calor2012)
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectPhysics
dc.subjectCalorimeters
dc.subjectCalorimetry
dc.subjectPhotodiodes
dc.subjectPhotons
dc.subjectAvalanche photo diode (apd)
dc.subjectCrystal material
dc.subjectElectromagnetic calorimeter
dc.subjectEnergy resolutions
dc.subjectGev electron beam
dc.subjectIncident particles
dc.subjectPin photodiode
dc.subjectPositron beams
dc.subjectHigh energy physics
dc.subject.scopusAvalanche Photodiodes; Dark Currents; Calorimeters
dc.subject.wosPhysics, multidisciplinary
dc.subject.wosPhysics, particles & fields
dc.titleSimulation work on calorimetric energy resolution for the TAC-PF detector
dc.typeconferenceObject
dc.type.subtypeProceedings Paper
dspace.entity.typePublication
local.contributor.departmentFen Edebiyat Fakültesi/Fizik Bölümü
local.indexed.atScopus
local.indexed.atWOS

Dosyalar

Orijinal seri

Şimdi gösteriliyor 1 - 1 / 1
Küçük Resim
Ad:
Tapan_Koçak_2012.pdf
Boyut:
820.24 KB
Format:
Adobe Portable Document Format
Açıklama

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Placeholder
Ad:
license.txt
Boyut:
1.71 KB
Format:
Item-specific license agreed upon to submission
Açıklama