Yayın:
Use of thermal images for optimizing burner height, operating pressure, and burner angle of a weed flamer

dc.contributor.authorArslan, S.
dc.contributor.authorTursun, N.
dc.contributor.authorKurtulmuş, F.
dc.contributor.authorGüleç, D.
dc.contributor.buuauthorARSLAN, SELÇUK
dc.contributor.buuauthorKURTULMUŞ, FERHAT
dc.contributor.departmentZiraat Fakültesi
dc.contributor.departmentBiyosistem Mühendisliği Bölümü
dc.contributor.scopusid7006604572
dc.contributor.scopusid15848202900
dc.date.accessioned2025-08-06T23:11:11Z
dc.date.issued2016-01-01
dc.description.abstractA two-meter wide prototype weed flamer was developed as a tool for thermal weed control. The weed flamer consists of an LPG tank, pressure regulator, back pressure valve, flow valves, and burners. The burner adjustments are flexible with height setting from 0 to 450 mm and flame angle setting from and 0 to 90°.The thermal camera images were studied at different heights (150, 200, 250, and 300 mm), burner angles (30 and 45°), and pressures (0.1, 0.15, 0.2, 0.25 MPa) to determine the best settings under stationary operating conditions. Based on thermal camera image results, it was found that the burner should be set at 200-250 mm with 0.2-0.25 MPa to obtain the highest temperatures and longest flames. The initial tests of the gas burning system were completed as a broadcast flaming machine and gas doses from 15 to 90 kg ha<sup>-1</sup> were applied from 0.25 m above the ground at 30° flaming angle at 0.2 MPa. The doseresponse curves of a weed (Convolvulus arvensis L.) were generated to determine the effectiveness of the weed flamer. C. arvensis could be controlled with gas doses from 40 to 82 kg ha<sup>-1</sup> depending on the growth stage at 14 day after treatment (DAT). The theoretical field capacity of the 2 m wide flamer varies from 0.32 to 1.62 ha h<sup>-1</sup> depending on the gas dose to be applied.
dc.identifier.endpage24
dc.identifier.issn1406-894X
dc.identifier.issue1
dc.identifier.scopus2-s2.0-84970005342
dc.identifier.startpage14
dc.identifier.urihttps://hdl.handle.net/11452/53696
dc.identifier.volume14
dc.indexed.scopusScopus
dc.language.isoen
dc.publisherEesti Pollumajandusulikool
dc.relation.journalAgronomy Research
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectWeed control
dc.subjectThermal image
dc.subjectLPG
dc.subjectFlaming
dc.subjectDose-response
dc.titleUse of thermal images for optimizing burner height, operating pressure, and burner angle of a weed flamer
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentZiraat Fakültesi/Biyosistem Mühendisliği Bölümü
local.indexed.atScopus
relation.isAuthorOfPublication9b4502dc-6cb5-4d3a-9630-5d68f82ba23e
relation.isAuthorOfPublication9f2df001-5114-41af-bedc-156aea59aba6
relation.isAuthorOfPublication.latestForDiscovery9b4502dc-6cb5-4d3a-9630-5d68f82ba23e

Dosyalar