Publication:
Effect of infill walls and plaster for a four storey r/c building

dc.contributor.authorKaplan, Onur
dc.contributor.authorGüney, Yücel
dc.contributor.authorDoğangün, Adem
dc.contributor.authorLivaoğlu, Ramazan
dc.contributor.authorAenlle, ML
dc.contributor.authorPelayo, F
dc.contributor.authorCanas, FJC
dc.contributor.authorPrieto, MG
dc.contributor.authorHermanns, L
dc.contributor.authorRey, MJL
dc.contributor.authorFraileDeLerma, A
dc.contributor.authorCanteli, AF
dc.contributor.buuauthorDOĞANGÜN, ADEM
dc.contributor.buuauthorLİVAOĞLU, RAMAZAN
dc.contributor.departmentUludağ Üniversitesi
dc.contributor.editorAenlle, ML
dc.contributor.editorPelayo, F
dc.contributor.editorCanas, FJC
dc.contributor.editorPrieto, MG
dc.contributor.editorHermanns, L
dc.contributor.editorRey, MJL
dc.contributor.editorFraileDeLerma, A
dc.contributor.editorCanteli, AF
dc.contributor.orcid0000-0002-1867-7103
dc.contributor.orcid0000-0001-8484-6027
dc.contributor.researcheridAAR-6126-2020
dc.contributor.researcheridS-4676-2019
dc.contributor.researcheridM-6474-2014
dc.date.accessioned2024-07-31T05:43:59Z
dc.date.available2024-07-31T05:43:59Z
dc.date.issued2015-01-01
dc.descriptionBu çalışma, 12-14, Mayıs 2015 tarihlerinde Gijon[İspanya]’da düzenlenen 6. International Operational Modal Analysis Conference (IOMAC) Kongresi‘nde bildiri olarak sunulmuştur.
dc.description.abstractInfill walls are non-structural elements, which are mainly used for architectural purposes. Besides contribution of infill walls is ignored during the structural analysis, the effect of the infill walls are usually taken into account through the application of additional loads and masses appropriately distributed along the interfaces between the surrounding frame and the infill walls. In doing so, the stiffness and strength contribution of the latter elements as well as their interaction with the members of the Reinforced Concrete (RC) frame are also ignored. Practically some of the earthquake design codes like Turkish code neglect the effects of the non-structural infill walls. However the presence of infill walls significantly increases the stiffness and the strength of a frame. The reasons of this increment are high in-plane stiffness of infill and the composite action of the infill and the frame. On the other hand, plastering significantly affects the behaviour of infill walls. Thus, the dynamic characteristics of a building also affected by the mu 11 walls of building having plaster or not.The objective of this study is selected to compare the behaviour of mull walls with and without plaster by focusing on dynamic characteristics of a 4-storey residential R/C building in Eskisehir, Turkey. Natural periods, mode shapes and damping ratios of the building were determined for two different construction stages by using ambient vibration test. To obtain experimental dynamic characteristics, Enhanced Frequency Domain Decomposition (EFDD) technique was used. These 4-storey residential R/C building is located in Eskisehir, Turkey. The investigated building in which seismic loads are jointly resisted by frames and structural walls. There are only one shear wall along x-direction and four shear walls along y-direction. The floor area of the building is 400 m(2) and story heights are 2.83 m. Total area of infill walls for one storey are 5.44 m(2) and 10.75 m(2) at x-direction y-direction, respectively.As a result of this study, vibration measurements are established that, plaster significantly changed the dynamic characteristics of building. Decrease in the periods both x and y directions and also torsional period showed that the plaster increases the lateral stiffness of the infill walls and thereby it increased the lateral stiffness of the building.
dc.description.sponsorshipBruel & Kjaer
dc.description.sponsorshipStructural Vibrat Solut
dc.description.sponsorshipInstrutechSOLUT
dc.description.sponsorshipUniv Aquila
dc.description.sponsorshipGijon Convent Bur
dc.description.sponsorshipUniv British Columbia
dc.identifier.endpage30
dc.identifier.startpage23
dc.identifier.urihttps://hdl.handle.net/11452/43560
dc.identifier.wos000365243600004
dc.indexed.wosWOS.ISTP
dc.language.isoen
dc.publisherEdiciones Univ Oviedo
dc.relation.journal6. Iomac: International Operational Modal Analysis Conference Proceedings
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectAmbient vibration
dc.subjectFrames
dc.subjectIdentification
dc.subjectPeriod
dc.subjectOperational
dc.subjectModal
dc.subjectAnalysis
dc.subjectVibration
dc.subjectAmbient
dc.subjectInfill
dc.subjectPlaster
dc.subjectPeriod
dc.subjectScience & technology
dc.subjectTechnology
dc.subjectConstruction & building technology
dc.subjectEngineering, civil
dc.subjectEngineering, mechanical
dc.subjectConstruction & building technology
dc.subjectEngineering
dc.titleEffect of infill walls and plaster for a four storey r/c building
dc.typeProceedings Paper
dspace.entity.typePublication
local.contributor.departmentUludağ Üniversitesi
relation.isAuthorOfPublication55182655-729b-48a9-99ce-20309a659de6
relation.isAuthorOfPublicationa24f409a-e682-432b-8e20-e1393c6199ee
relation.isAuthorOfPublication.latestForDiscovery55182655-729b-48a9-99ce-20309a659de6

Files