Yayın:
Regeneration of industrial district wastewater using a combination of Fenton process and ion exchange - A case study

dc.contributor.buuauthorÜstün, Gökhan Ekrem
dc.contributor.buuauthorSolmaz, Seval Kutlu Akal
dc.contributor.buuauthorBirgül, Aşkın
dc.contributor.departmentMühendislik Fakültesi
dc.contributor.departmentÇevre Mühendisliği Bölümü
dc.contributor.orcid0000-0002-7718-0340
dc.contributor.orcid0000-0002-7126-6792
dc.contributor.researcheridF-7879-2015
dc.contributor.researcheridAAH-1967-2021
dc.contributor.researcheridF-7879-2015
dc.contributor.scopusid6602601167
dc.contributor.scopusid8630493800
dc.contributor.scopusid12795386100
dc.date.accessioned2022-08-18T07:54:10Z
dc.date.available2022-08-18T07:54:10Z
dc.date.issued2007-12
dc.description.abstractRegeneration studies of wastewater effluent from an organized industrial district (OID) for possible reuse in textile industry as process water was investigated. Advanced treatment methods including Fenton process, polyaluminium chloride (PAC) coagulation and ion exchange were applied on OID effluent. In Fenton process removal efficiencies for suspended solids (SS), chemical oxygen demand (COD), SAC(436) (spectral absorption coefficient), SAC(525) and SAC(620) were determined 61%, 36%, 35%, 49% and 67%, respectively. After Fenton process, wastewater samples were coagulated with PAC. Optimum removal efficiencies for SS, COD, Fe ion, SAC(436), SAC(525) and SAC(620) were determined 83%, 18%, 93%, 32%, 36% and 58%, respectively. Ion exchange experiments were conducted on chemically coagulated wastewater samples to improve the quality of wastewater. Optimum dosage of resins was determined. The experiments revealed that 1:1 resin ratio (20 mL H-type resin:20 mL OH-type resin) gave the best removal rates for the parameters considered in this study. Study results indicated that quality of the wastewater was suitable for the process water characteristics of textile industry and unit wastewater treatment cost was determined as 2.54 is an element of/m(3).
dc.identifier.citationÜstün, G. E. vd. (2007). "Regeneration of industrial district wastewater using a combination of Fenton process and ion exchange - A case study". Resources Conservation and Recyling, 52(2), 425-440.
dc.identifier.doi10.1016/j.resconrec.2007.05.006
dc.identifier.endpage440
dc.identifier.issn0921-3449
dc.identifier.issn1879-0658
dc.identifier.issue2
dc.identifier.scopus2-s2.0-34548846397
dc.identifier.startpage425
dc.identifier.urihttps://doi.org/10.1016/j.resconrec.2007.05.006
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0921344907001425
dc.identifier.urihttp://hdl.handle.net/11452/28245
dc.identifier.volume52
dc.identifier.wos000250633600017
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherElsevier
dc.relation.journalResources Conservation and Recycling
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectFenton process
dc.subjectAbsorption
dc.subjectChemical oxygen demand
dc.subjectEffluents
dc.subjectFenton process
dc.subjectWastewater treatment
dc.subjectIon exchange
dc.subjectOID wastewater
dc.subjectProcess water characteristic
dc.subjectReuse
dc.subjectTextile industry
dc.subjectPolyaluminium chloride
dc.subjectWater characteristics
dc.subjectChemical oxygen demand
dc.subjectCoagulation
dc.subjectEffluents
dc.subjectReusability
dc.subjectPollutant removal
dc.subjectTextile industry
dc.subjectIndustrial waste
dc.subjectRecycling
dc.subjectTextile industry
dc.subject.emtreeIron
dc.subject.emtreeArticle
dc.subject.emtreeResin
dc.subject.emtreeChemical oxygen demand
dc.subject.emtreeFenton reaction
dc.subject.emtreeIon exchange
dc.subject.emtreeSpectroscopy
dc.subject.emtreeSuspended particulate matter
dc.subject.emtreeTextile industry
dc.subject.emtreeWaste water
dc.subject.emtreeWaste water management
dc.subject.emtreeWater quality
dc.subject.emtreeWater sampling
dc.subject.scopusFlocculants; Sewage Systems; Dimethylamines
dc.subject.wosEngineering, environmenteal
dc.subject.wosEnvironmental sciences
dc.titleRegeneration of industrial district wastewater using a combination of Fenton process and ion exchange - A case study
dc.typeArticle
dc.wos.quartileQ2 (Engineering, environmental)
dc.wos.quartileQ3 (Environmental sciences)
dspace.entity.typePublication
local.contributor.departmentMühendislik Fakültesi/Çevre Mühendisliği Bölümü
local.indexed.atScopus
local.indexed.atWOS

Dosyalar

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Placeholder
Ad:
license.txt
Boyut:
1.71 KB
Format:
Item-specific license agreed upon to submission
Açıklama