Yayın:
Experimental and numerical investigation of pressure drop coefficient and static pressure difference in a tangential inlet cyclone separator

Placeholder

Tarih

Akademik Birimler

Kurum Yazarları

Karagöz, İrfan

Yazarlar

Kaya, Fuat

Danışman

Dil

Türü

Yayıncı:

Springer

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Özet

The aim of this study was to investigate the pressure drop coefficient and the static pressure difference related to the natural vortex length and to evaluate the results for gas-particle applications. CFD simulations were carried out using a numerical technique which had been verified previously. Results obtained from the numerical simulations were compared with the experimental data. Analysis of the results showed that the pressure drop coefficient decreases with the increasing inlet velocity, becoming almost constant above a certain value of the inlet velocity. The reason is that the effect of viscous forces decreases at high Reynolds numbers. The pressure drop coefficient also decreases with the increasing exit pipe diameter and decreasing exit pipe length.

Açıklama

Kaynak:

Anahtar Kelimeler:

Konusu

Chemistry, Swirling flows, Cfd, Pressure drop, Pressure drop coefficient, Particle flow, Gas cyclone, Performance, Collection

Alıntı

Kaya, F. ve Karagöz, İ. (2012). "Experimental and numerical investigation of pressure drop coefficient and static pressure difference in a tangential inlet cyclone separator". Chemical Papers, 66(11), 1019-1025.