Yayın:
Comparative results of percutaneous cannulated screws, dynamic compression type plate and screw for the treatment of femoral neck fractures

dc.contributor.authorKaplan, Tolga
dc.contributor.buuauthorAkesen, Burak
dc.contributor.buuauthorDemirağ, Burak
dc.contributor.buuauthorBilgen, Sadık
dc.contributor.buuauthorDurak, Kemal
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentOrtopedi ve Travmatoloji Ana Bilim Dalı
dc.contributor.researcheridAAI-1638-2021
dc.contributor.researcheridAAH-9833-2021
dc.contributor.scopusid23102160500
dc.contributor.scopusid56019156900
dc.contributor.scopusid15061239900
dc.contributor.scopusid6602850051
dc.date.accessioned2022-05-23T11:14:30Z
dc.date.available2022-05-23T11:14:30Z
dc.date.issued2012-01
dc.description.abstractBACKGROUND The purpose of this study was to compare the period of union, functional outcomes and complications of patients with femoral neck fracture treated with percutaneous cannulated screws versus dynamic hip screw (DHS). METHODS Sixty-six patients with femoral neck fracture were treated with percutaneous cannulated screws (n=33) or with DHS (n=33) between August 1999 and October 2003. Functional outcome was measured using Harris Hip Score, and period of union, amount of bleeding and complications were also recorded. RESULTS The period of union and functional outcomes were not different between the two groups. Risk of avascular necrosis (AVN) was associated mainly with the grade of fracture displacement. In the percutaneous cannulated screw group, duration of surgery was shorter and blood loss was less than in the other group. CONCLUSION There was no superiority between cannulated screws and DHS according to union times and functional results. Risk of AVN is related to the degree of displacement. However, a prospective randomized study is needed to determine the outcome of each technique for patients suffering similar displacement rates.
dc.identifier.citationKaplan, T. vd. (2012). "Comparative results of percutaneous cannulated screws, dynamic compression type plate and screw for the treatment of femoral neck fractures". Ulusal Travma ve Acil Cerrahi Dergisi-Turkish Journal of Trauma & Emergency Surgery, 18(1), 65-70.
dc.identifier.doi10.5505/tjtes.2012.33427
dc.identifier.endpage70
dc.identifier.issn1306-696X
dc.identifier.issue1
dc.identifier.pubmed22290053
dc.identifier.scopus2-s2.0-84855802596
dc.identifier.startpage65
dc.identifier.urihttps://doi.org/10.5505/tjtes.2012.33427
dc.identifier.urihttps://tjtes.org/jvi.aspx?pdir=travma&plng=eng&volume=18&issue=1
dc.identifier.urihttp://hdl.handle.net/11452/26610
dc.identifier.volume18
dc.identifier.wos000300521700013
dc.indexed.scopusScopus
dc.indexed.trdizinTrDizin
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherTürk Travma ve Acil Cerrahi Dergisi
dc.relation.collaborationSanayi
dc.relation.journalUlusal Travma ve Acil Cerrahi Dergisi-Turkish Journal of Trauma & Emergency Surgery
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEmergency medicine
dc.subjectDynamic hip screw
dc.subjectFractures of the femoral neck
dc.subjectPercutaneous
dc.subjectCannulated screw
dc.subjectIntracapsular fractures
dc.subjectHip-fractures
dc.subjectProximal femur
dc.subjectSubcapital fractures
dc.subjectFixation
dc.subjectRehabilitation
dc.subjectManagement
dc.subjectOutcomes
dc.subjectSweden
dc.subjectSystem
dc.subject.emtreeAdult
dc.subject.emtreeAged
dc.subject.emtreeArticle
dc.subject.emtreeAvascular necrosis
dc.subject.emtreeBleeding
dc.subject.emtreeBone plate
dc.subject.emtreeBone screw
dc.subject.emtreeControlled study
dc.subject.emtreeDynamic hip screw
dc.subject.emtreeFemale
dc.subject.emtreeFemur neck fracture
dc.subject.emtreeFracture healing
dc.subject.emtreeHarris hip score
dc.subject.emtreeHuman
dc.subject.emtreeIntermethod comparison
dc.subject.emtreeInternal fixator
dc.subject.emtreeMajor clinical study
dc.subject.emtreeMale
dc.subject.emtreeOperation duration
dc.subject.emtreeOsteosynthesis
dc.subject.emtreePercutaneous cannulated screw
dc.subject.emtreePostoperative complication
dc.subject.emtreeRetrospective study
dc.subject.emtreeTreatment outcome
dc.subject.scopusFemoral Neck Fractures; Hemiarthroplasty; Femur Neck
dc.subject.wosEmergency medicine
dc.titleComparative results of percutaneous cannulated screws, dynamic compression type plate and screw for the treatment of femoral neck fractures
dc.title.alternativeFemur boyun kırıklarının tedavisinde perkütan kanüle vida, dinamik kompresyon plak ve vidanın karşılaştırmalı sonuçları
dc.typeArticle
dc.wos.quartileQ4
dc.wos.quartileQ4
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Ortopedi ve Travmatoloji Ana Bilim Dalı
local.indexed.atTrDizin
local.indexed.atWOS
local.indexed.atScopus

Dosyalar

Orijinal seri

Şimdi gösteriliyor 1 - 1 / 1
Küçük Resim
Ad:
Akesen_vd_2012.pdf
Boyut:
3.3 MB
Format:
Adobe Portable Document Format
Açıklama

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Placeholder
Ad:
license.txt
Boyut:
1.71 KB
Format:
Item-specific license agreed upon to submission
Açıklama