Yayın: Modified Y-configured stents with the waffle-cone technique by use of solitaire® stent for patients with wide-necked bifurcation aneurysms
Tarih
Kurum Yazarları
Yazarlar
Nas, Ömer Fatih
Kaçar, Emre
Kaya, Ahmet
Erdoğan, Cüneyt
Hakyemez, Bahattin
Danışman
Dil
Türü
Yayıncı:
Springer
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Özet
Endovascular treatment of wide-necked bifurcation aneurysms can be challenging, despite improvements in endovascular techniques. Y stent-assisted coiling is one such technique, but this may not be technically feasible, especially in cases of acute angulation between the proximal and distal parent arteries, and may require use of "modified Y-configured stents with the waffle-cone technique". We report three cases of wide-necked bifurcation aneurysms that were successfully treated by use of the Solitaire (R) stent.
Açıklama
Kaynak:
Anahtar Kelimeler:
Konusu