Yayın: Comparison of the simulated gamma-ray attenuation coefficients with the real measurements
Tarih
Kurum Yazarları
Piliçer, Ercan
Yazarlar
Ermiş, E.
Piliçer, E.
Çeliktaş, C.
Danışman
Dil
Türü
Yayıncı:
Science Press
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Özet
The gamma-ray linear and the mass attenuation coefficients of Pb, Al, Cu, and plexiglass materials were calculated from both experimental and theoretical (simulation) methods. For the experimental results, a spectrometer, which was consisted of a NaI(Tl) inorganic scintillation detector, was used. The theoretical attenuation values were calculated by means of the FLUKA Monte Carlo (MC) and XCOM programs. Obtained attenuation coefficients from the experiment and the theoretical methods were compared with each other and literature values.
Açıklama
Kaynak:
Anahtar Kelimeler:
Konusu
XCOM, NaI(Tl) scintillation detector, Gamma attenuation coefficients, FLUKA
