Numerical investigation of the effect of radiator placement on temperature distribution in a room

dc.contributor.authorUfat, Hande
dc.contributor.buuauthorUFAT, HANDE
dc.contributor.departmentTeknik Bilimler Meslek Yüksekokulu
dc.contributor.departmentİklimlendirme ve Soğutma Programı
dc.contributor.scopusid57195235906
dc.date.accessioned2025-05-12T22:32:58Z
dc.date.issued2024-01-01
dc.description.abstractThis study analyses the impact of radiator placement on temperature distribution in a room using CFD analysis. Radiators are typically placed under windows or on outer walls. However, in the area under study, where there are large windows extending to the floor on the outer walls, the radiator was positioned on the empty inner wall. Two variations of the analysis were conducted using the ANSYS Fluent program. One variation involved a vertical installation of an aluminium panel radiator of the same length as the existing radiator on the outer wall next to one of the two windows. The other variation involved the installation of two radiators of the same length as the existing radiator next to the windows. The results showed that the room heated up faster when two radiators were used compared to other alternatives. Heating a room with two radiators of equal length and surface temperature results in a faster temperature increase. When a radiator is positioned vertically, the average temperature remains the same as the current situation. Using multiple smaller radiators instead of a single large one that provides the same amount of heat allowed the environment to warm up more quickly.
dc.identifier.doi10.1504/PCFD.2024.142057
dc.identifier.endpage376
dc.identifier.issn1468-4349
dc.identifier.issue6
dc.identifier.scopus2-s2.0-85206498254
dc.identifier.startpage367
dc.identifier.urihttps://hdl.handle.net/11452/51358
dc.identifier.volume24
dc.indexed.scopusScopus
dc.language.isoen
dc.publisherInderscience Publishers
dc.relation.journalProgress in Computational Fluid Dynamics
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectThermal comfort
dc.subjectTemperature distribution
dc.subjectPanel radiator
dc.subjectCFD analysis
dc.subject.scopusEnergy Conservation; Heating Equipment; Computational Fluid Dynamics
dc.titleNumerical investigation of the effect of radiator placement on temperature distribution in a room
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentTeknik Bilimler Meslek Yüksekokulu/İklimlendirme ve Soğutma Programı
relation.isAuthorOfPublicationcab4b402-f903-47b5-9be3-9226784b7f67
relation.isAuthorOfPublication.latestForDiscoverycab4b402-f903-47b5-9be3-9226784b7f67

Files

Collections