Publication: Calculation of angular distribution of 662 keV gamma rays by Monte Carlo method in copper medium
dc.contributor.author | Yalçın, Sezai | |
dc.contributor.author | Gündoğdu, Özcan | |
dc.contributor.buuauthor | Kahraman, Arda | |
dc.contributor.buuauthor | Özmutlu, Emin N. | |
dc.contributor.buuauthor | Güler, Orhan | |
dc.contributor.buuauthor | Kaynak, Gökay | |
dc.contributor.department | Fen Edebiyat Fakültesi | |
dc.contributor.department | Fizik Bölümü | |
dc.contributor.researcherid | AAH-1837-2021 | |
dc.contributor.scopusid | 47161190600 | |
dc.contributor.scopusid | 6507726213 | |
dc.contributor.scopusid | 14019444500 | |
dc.contributor.scopusid | 12042075600 | |
dc.date.accessioned | 2022-03-22T12:05:06Z | |
dc.date.available | 2022-03-22T12:05:06Z | |
dc.date.issued | 2009-12 | |
dc.description | Bu çalışma, 25-27 Şubat 2009 tarihleri arasında Vienna[Avusturya]’da düzenlenen 22. Seminar on Activation Analysis and Gamma Spectroscopy’da bildiri olarak sunulmuştur. | |
dc.description.abstract | This paper presents results on the angular distribution of Compton scattering of 662 keV gamma photons in both forward and backward hemispheres in copper medium. The number of scattered events graph has been determined for scattered gamma photons in both the forward and backward hemispheres and theoretical saturation thicknesses have been obtained using these results. Furthermore, response function of a 51 x 51 mm Nal(Tl) detector at 60 degrees angle with incoming photons scattered from a 10mm thick copper layer has been determined using Monte Carlo method. | |
dc.identifier.citation | Kahraman, A. vd. (2009). "Calculation of angular distribution of 662 keV gamma rays by Monte Carlo method in copper medium". Applied Radiation and Isotopes, 67(12), 2083-2087. | |
dc.identifier.endpage | 2087 | |
dc.identifier.issn | 0969-8043 | |
dc.identifier.issue | 12 | |
dc.identifier.pubmed | 19487129 | |
dc.identifier.scopus | 2-s2.0-70349805061 | |
dc.identifier.startpage | 2083 | |
dc.identifier.uri | https://doi.org/10.1016/j.apradiso.2009.04.013 | |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0969804309003728 | |
dc.identifier.uri | http://hdl.handle.net/11452/25271 | |
dc.identifier.volume | 67 | |
dc.identifier.wos | 000271482800005 | |
dc.indexed.wos | SCIE | |
dc.indexed.wos | CPCIS | |
dc.language.iso | en | |
dc.publisher | Pergamon-Elsevier Science | |
dc.relation.collaboration | Yurt içi | |
dc.relation.collaboration | Yurt dışı | |
dc.relation.journal | Applied Radiation and Isotopes | |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası | |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.subject | Angular distribution | |
dc.subject | Compton scattered events | |
dc.subject | Monte Carlo | |
dc.subject | Multiple-scattering | |
dc.subject | Photon | |
dc.subject | Chemistry | |
dc.subject | Nuclear science & technology | |
dc.subject | Radiology, nuclear medicine & medical imaging | |
dc.subject | Compton scattering | |
dc.subject | Copper | |
dc.subject | Gamma rays | |
dc.subject | Monte Carlo methods | |
dc.subject | Photons | |
dc.subject | Compton scattered events | |
dc.subject | Copper layer | |
dc.subject | Gamma photons | |
dc.subject | Monte Carlo | |
dc.subject | NaI detector | |
dc.subject | Response functions | |
dc.subject | Scattered events | |
dc.subject | Angular distribution | |
dc.subject.emtree | Copper | |
dc.subject.emtree | Article | |
dc.subject.emtree | Electric potential | |
dc.subject.emtree | Gamma radiation | |
dc.subject.emtree | Mathematical computing | |
dc.subject.emtree | Mathematical model | |
dc.subject.emtree | Measurement | |
dc.subject.emtree | Monte Carlo method | |
dc.subject.emtree | Photon | |
dc.subject.emtree | Priority journal | |
dc.subject.emtree | Radiation scattering | |
dc.subject.emtree | Thickness | |
dc.subject.scopus | Compton Scattering; Scatter; Computer Assisted Tomography | |
dc.subject.wos | Chemistry, inorganic & nuclear | |
dc.subject.wos | Nuclear science & technology | |
dc.subject.wos | Radiology, nuclear medicine & medical imaging | |
dc.title | Calculation of angular distribution of 662 keV gamma rays by Monte Carlo method in copper medium | |
dc.type | Article | |
dc.type | Proceedings Paper | |
dc.wos.quartile | Q3 | |
dc.wos.quartile | Q2 (Nuclear science & technology) | |
dspace.entity.type | Publication | |
local.contributor.department | Fen Edebiyat Fakültesi/Fizik Bölümü | |
local.indexed.at | PubMed | |
local.indexed.at | WOS |
Files
License bundle
1 - 1 of 1
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: