Yayın:
Interobserver reliability in evaluation of pedicle screw positions inserted with a modified technique

dc.contributor.buuauthorÖzer, Özgür
dc.contributor.buuauthorÖztürk, Çaǧatay
dc.contributor.buuauthorAkesen, Burak
dc.contributor.buuauthorAydınlı, Ufuk
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentOrtopedik Cerrahi Ana Bilim Dalı
dc.contributor.orcid0000-0003-3133-206X
dc.contributor.researcheridAAH-9833-2021
dc.contributor.researcheridS-6686-2019
dc.contributor.scopusid8230556100
dc.contributor.scopusid8230555600
dc.contributor.scopusid23102160500
dc.contributor.scopusid6602800134
dc.date.accessioned2024-03-08T11:13:59Z
dc.date.available2024-03-08T11:13:59Z
dc.date.issued2007-08
dc.description.abstractThe aim of this study was to evaluate a new technique for insertion of pedicle screws. The position of the screws was assessed on postoperative plain radiographs and computed tomography (CT) scans, and the interobserver reliability in evaluation of the pedicle screw positions was studied. The technique was applied to insert 201 pedicle screws in 27 patients with various spine conditions. The positions of the screws were evaluated blindly by two independent orthopaedic surgeons and two independent radiologists. Interobserver reliability was evaluated separately for analysis of plain radiographs and CT scans, as well as for the different spinal segments and for the different spine conditions treated. The rate of malpositioned screws was between 6.5% and 32.8% in plain radiographs and between 3.5% and 6.5% in CT scans according to the different observers. In plain radiographs, the rates of malpositioned screws in the upper thoracic, lower thoracic and lumbosacral spine segments were between 3.8%-39.6%, 10.0%-36.3%, 4.4%-23.5%, respectively. In CT scans, the rates of malpositioned screws in the upper thoracic, lower thoracic and lumbosacral spine segments were between 3.8%-13.2%, 2.5%-8.8%, and 0%, respectively. Interobserver reliability was found to be poor in radiographs and fair in CT scans. The technique used for insertion of pedicle screws was found to be simple and reproducible. Assessment of the screw positions with only plain radiographs was not found reliable. A detailed and standard classification system should be developed in order to improve interobserver reliability in assessing the positions of the screws.
dc.identifier.citationÖzer, Ö. vd. (2007). "Interobserver reliability in evaluation of pedicle screw positions inserted with a modified technique". Acta Orthopaedica Belgica, 73(4), 491-499.
dc.identifier.endpage499
dc.identifier.issn0001-6462
dc.identifier.issue4
dc.identifier.pubmed17939480
dc.identifier.scopus2-s2.0-34548845349
dc.identifier.startpage491
dc.identifier.urihttps://hdl.handle.net/11452/40303
dc.identifier.volume73
dc.identifier.wos000254244900012
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherActa Medica Belgica
dc.relation.journalActa Medica Belgica
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectInsertion technique
dc.subjectPedicle screw
dc.subjectInterobserver reliability
dc.subjectThoracic spine
dc.subjectLumbar pedicle
dc.subjectInjuries
dc.subjectPlacement
dc.subjectInstrumentation
dc.subjectFixation
dc.subjectHooks
dc.subjectOrthopedics
dc.subject.emtreeAdolescent
dc.subject.emtreeAdult
dc.subject.emtreeArticle
dc.subject.emtreeBone screw
dc.subject.emtreeChild
dc.subject.emtreeFemale
dc.subject.emtreeHuman
dc.subject.emtreeMale
dc.subject.emtreeMethodology
dc.subject.emtreeMiddle aged
dc.subject.emtreeObserver variation
dc.subject.emtreeOrthopedic surgery
dc.subject.emtreePreschool child
dc.subject.emtreeRadiography
dc.subject.emtreeSpine
dc.subject.emtreeSpine disease
dc.subject.meshAdolescent
dc.subject.meshAdult
dc.subject.meshBone screws
dc.subject.meshChild
dc.subject.meshChild, preschool
dc.subject.meshFemale
dc.subject.meshHumans
dc.subject.meshMale
dc.subject.meshMiddle aged
dc.subject.meshObserver variation
dc.subject.meshOrthopedic procedures
dc.subject.meshSpinal diseases
dc.subject.meshSpine
dc.subject.scopusPedicle Screws; Scoliosis; Placement
dc.subject.wosOrthopedics
dc.titleInterobserver reliability in evaluation of pedicle screw positions inserted with a modified technique
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Ortopedik Cerrahi Ana Bilim Dalı
local.indexed.atWOS
local.indexed.atScopus
local.indexed.atPubMed

Dosyalar

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Placeholder
Ad:
license.txt
Boyut:
1.71 KB
Format:
Item-specific license agreed upon to submission
Açıklama