Yayın:
Huge thrombus formation 1 year after percutaneous closure of an atrial septal defect with an Amplatzer septal occluder

Küçük Resim

Akademik Birimler

Kurum Yazarları

Uysal, Fahrettin
Bostan, Özlem Mehtap
Sığnak, Işık Şenkaya
Güneş, Mustafa
Çil, Ergün

Yazarlar

Danışman

Dil

Türü

Yayıncı:

Aves

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Özet

The Amplatzer septal occluder (ASO) has become the device of choice for interventional closure of atrial septal defects (ASDs) in many institutions during the last decades. Although excellent results have been reported for the device, concerns have arisen about the long-term complications (1). Of these complications, thrombus formation was rarely seen after 1 year in patients (2–4). This is the first report of a pediatric patient of a huge thrombus developing on an ASO device detected by transthoracic echocardiography on a routine examination after 1 year of implantation without a risk factor.