Yayın:
Assessment of single- and dual-PUF-containing passive air samplers for the collection of atmospheric PAHs

dc.contributor.authorÇalışkan B.
dc.contributor.author Çelik, Semra
dc.contributor.authorTaşdemir, Yücel
dc.contributor.buuauthorÇALIŞKAN, BURAK
dc.contributor.buuauthorÇelik, Semra
dc.contributor.buuauthorTAŞDEMİR, YÜCEL
dc.contributor.departmentMühendislik Fakültesi
dc.contributor.departmentÇevre Mühendisliği Bölümü
dc.contributor.scopusid57211119035
dc.contributor.scopusid58317644100
dc.contributor.scopusid6603118338
dc.date.accessioned2025-05-12T22:26:55Z
dc.date.issued2024-03-01
dc.description.abstractIn this study, atmospheric polycyclic aromatic hydrocarbons (PAHs) were determined in fifteen individual, consecutive sampling events conducted in a semi-urban area of Bursa between June 2021 and February 2022 using passive air samplers (PASs). In this study, PASs containing single and dual PUF disks were used simultaneously and side by side. The aim of this study was to compare the results obtained from PASs containing single and dual PUF disks in terms of mass and number of PAH compounds. To our knowledge, the use of PASs containing dual PUF disks was applied for the first time in the literature. Because of the extended surface area, dual PUFs containing PAS can sample and detect more atmospheric PAHs. PAH masses in both samplers had a decreasing relationship with temperature. During the sampling period, the total masses of PAHs (∑16 PAH) were calculated as 1058 ± 1042 ng (117–3380 ng) on single-PUF disks and 1930 ± 1749 ng (279–5640 ng) on dual-PUF disks. The ratio of the dual-PUF value to the single-PUF value for ∑16 PAH in the samples varied between 1.41 and 3.45 (1.99 ± 0.50). Moreover, when the single and dual PUF mass results were evaluated on a compound basis, high correlation results were obtained. The sampling characteristics of both samplers were interpreted with the effect of possible PAH sources. It was determined that both samplers were affected by the same sources in the region due to the high similarities in diagnostic ratios. The main sources of PAHs were primarily residential heating and vehicle emissions.
dc.identifier.doi10.1016/j.apr.2023.102009
dc.identifier.issn1309-1042
dc.identifier.issue3
dc.identifier.scopus2-s2.0-85179796764
dc.identifier.urihttps://hdl.handle.net/11452/51304
dc.identifier.volume15
dc.indexed.scopusScopus
dc.language.isoen
dc.publisherElsevier
dc.relation.bapFGA-2021-621
dc.relation.journalAtmospheric Pollution Research
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectSource
dc.subjectSemi-urban
dc.subjectPassive sampling
dc.subjectAtmosphere
dc.titleAssessment of single- and dual-PUF-containing passive air samplers for the collection of atmospheric PAHs
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentMühendislik Fakültesi/Çevre Mühendisliği Bölümü
local.indexed.atScopus
relation.isAuthorOfPublicationf52633c1-8c68-45a3-b9a3-e525179d00ed
relation.isAuthorOfPublicationfbf62f36-f164-4c66-8124-a194620c7ae5
relation.isAuthorOfPublication.latestForDiscoveryf52633c1-8c68-45a3-b9a3-e525179d00ed

Dosyalar