Yayın:
Factors affecting the measurements of peripheral oxygen saturation values in healthy young adults

dc.contributor.authorUysal, Oktay
dc.contributor.authorYilmaz, Dilek
dc.contributor.buuauthorYILMAZ, DİLEK
dc.contributor.departmentSağlık Bilimleri Fakültesi
dc.contributor.departmentHemşirelik Ana Bilim Dalı
dc.contributor.researcheridV-6292-2018
dc.date.accessioned2025-10-14T06:26:01Z
dc.date.issued2025-06-12
dc.description.abstractObjectives The aim of the study was to examine peripheral oxygen saturation values in the index and middle fingers of the dominant hand in healthy young adults measured while lying in a supine position or sitting straight up. Methods This study was a non-randomized and non-controlled, quasi-experimental repeated measures study. It was conducted with 200 healthy young adults in Turkey. A pulse oximeter was located at the same time on the index and middle fingers of the active hand of each participant while sitting upright, and after being kept there for 1 min, the results of the measurements were recorded. Later, the participants were brought into a supine position, and after 10 min of rest, measurements with a pulse oximeter placed on the index and middle fingers of the active hand were repeated in the same way. Results The mean age of the participants was 20.4 +/- 1.8 years; 76.5% were female, and their mean body mass index was 22.5 +/- 3.6 kg/m2. It was found that when the individuals were sitting upright, the peripheral oxygen saturation values measured from the middle finger were significantly higher than the peripheral oxygen saturation values measured from the middle finger in the supine position (p = 0.003). It was found that the peripheral oxygen saturation values of female participants measured from the index finger in the upright sitting position and from the index and middle fingers in the supine position were significantly higher than the saturation values of male participants (p = 0.018, p < 0.001, p = 0.001, respectively). In addition, it was found that the peripheral oxygen saturation values measured from the index and middle fingers of underweight individuals in the sitting position and from the index and middle fingers in the supine position were significantly higher than the saturation values of overweight individuals (p = 0.021, p = 0.006, p = 0.001, respectively). Conclusion In the conclusions of this study, it was found that the highest oxygen saturation value of the young adults was measured from the middle finger when they were in the upright sitting position. It was also found that the variables of gender and body mass index significantly affected the peripheral oxygen saturation value.
dc.identifier.doi10.1515/med-2025-1219
dc.identifier.issn2391-5463
dc.identifier.issue1
dc.identifier.scopus2-s2.0-105009822461
dc.identifier.urihttps://doi.org/10.1515/med-2025-1219
dc.identifier.urihttps://hdl.handle.net/11452/55522
dc.identifier.volume20
dc.identifier.wos001515396600001
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherDe Gruyter Poland
dc.relation.bapBAP
dc.relation.journalOpen Medicine
dc.subjectbody positions
dc.subjecthealthy individuals
dc.subjectperipheral oxygen saturation
dc.subjectoxygenation
dc.subjectpulse oximeter
dc.subjectScience & Technology
dc.subjectLife Sciences & Biomedicine
dc.subjectMedicine, General & Internal
dc.subjectGeneral & Internal Medicine
dc.titleFactors affecting the measurements of peripheral oxygen saturation values in healthy young adults
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentSağlık Bilimleri Fakültesi/Hemşirelik Ana Bilim Dalı
local.indexed.atWOS
local.indexed.atScopus
relation.isAuthorOfPublicationc350a208-f5f7-427c-b1a7-2b570bbd3d13
relation.isAuthorOfPublication.latestForDiscoveryc350a208-f5f7-427c-b1a7-2b570bbd3d13

Dosyalar

Orijinal seri

Şimdi gösteriliyor 1 - 1 / 1
Küçük Resim
Ad:
Uysal_Yilmaz_2025.pdf
Boyut:
496.97 KB
Format:
Adobe Portable Document Format