Yayın:
Acute haemodialysis-induced changes in tissue doppler echocardiography parameters

dc.contributor.buuauthorSaǧ, Saim
dc.contributor.buuauthorYeşilbursa, Dilek
dc.contributor.buuauthorYıldız, Abdülmecit
dc.contributor.buuauthorDilek, Kamil
dc.contributor.buuauthorŞentürk, T.
dc.contributor.buuauthorSerdar, Osman Akın
dc.contributor.buuauthorAydınlar, Ali Altun
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentKardiyoloji Ana Bilim Dalı
dc.contributor.departmentNefroloji Ana Bilim Dalı
dc.contributor.orcid0000-0002-8974-8837
dc.contributor.orcid0000-0001-8404-8252
dc.contributor.researcheridAAI-6632-2021
dc.contributor.researcheridAAF-5116-2019
dc.contributor.researcheridC-1517-2017
dc.contributor.researcheridAAW-9185-2020
dc.contributor.scopusid12140008100
dc.contributor.scopusid36658194500
dc.contributor.scopusid56256977500
dc.contributor.scopusid56005080200
dc.contributor.scopusid8342098300
dc.contributor.scopusid6507416315
dc.contributor.scopusid6603131517
dc.date.accessioned2024-02-14T05:50:51Z
dc.date.available2024-02-14T05:50:51Z
dc.date.issued2014-07-23
dc.description.abstractBackground: Tissue Doppler imaging (TDI) is a method that determines the tissue motion and velocity within the myocardium. Aims: To characterize acute haemodialysis (HD)-induced changes in TDI-derived indices for patients that have end-stage renal disease (ESRD). Study Design: Cross sectional study. Methods: Conventional echocardiography and TDI methods were applied to study ESRD patients (n=58) before and after HD. Pulmonary venous flow, mitral inflow, and TDI signals of the lateral and septal mitral annulus were examined for the determination of altered left-ventricular diastolic filling parameters. Flow velocities from early-(E) and late-atrial (A) peak transmitral; peak pulmonary vein systolic (S) and diastolic (D); and myocardial peak systolic (Sm) and peak early (Em) and late (Am) diastolic mitral annular velocities were also assessed for changes. Results: Transmitral E and A velocities and the E/A ratio decreased significantly after HD (p<0.001). Pulmonary vein S (p<0.001) and D (p<0.001) velocities decreased, and S/D ratios increased significantly (p=0.027). HD led to a reduction in septal Em (p<0.001), lateral Em (p=0.006), and Am (p<0.001) velocities. Contrary to the decreases in Em and Am, the Em/Am ratio remained unchanged. Conclusion: A single HD session was associated with an acute deterioration in the diastolic parameters. Since the Em/Am ratio remained unchanged, we conclude that this index is a relatively load-independent measure of diastolic function in HD patients.
dc.identifier.citationSaǧ, S. vd. (2014). "Acute haemodialysis-induced changes in tissue doppler echocardiography parameters". Balkan Medical Journal, 31(3), 239-243.
dc.identifier.doi10.5152/balkanmedj.2014.13170
dc.identifier.endpage243
dc.identifier.issn2146-3123
dc.identifier.issn2146-3131
dc.identifier.issue3
dc.identifier.pubmed25337420
dc.identifier.scopus2-s2.0-84907273179
dc.identifier.startpage239
dc.identifier.urihttps://doi.org/10.5152/balkanmedj.2014.13170
dc.identifier.urihttps://www.balkanmedicaljournal.org/uploads/pdf/pdf_BMJ_292.pdf
dc.identifier.urihttps://hdl.handle.net/11452/39685
dc.identifier.volume31
dc.identifier.wos000346137300011
dc.indexed.wosSCIE
dc.indexed.wosCPCIS
dc.language.isoen
dc.publisherGalenos Publ House
dc.relation.journalBalkan Medical Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEchocardiography
dc.subjectTissue Doppler imaging
dc.subjectHaemodialysis
dc.subjectLeft ventricular systolic and diastolic function
dc.subjectLeft-ventricular function
dc.subjectPreload
dc.subjectChronic kidney-disease
dc.subjectMortality
dc.subjectDialysis patients
dc.subjectGeneral & internal medicine
dc.subject.emtreeAdult
dc.subject.emtreeArticle
dc.subject.emtreeCoronary artery blood flow
dc.subject.emtreeCross-sectional study
dc.subject.emtreeDiastole
dc.subject.emtreeDoppler device
dc.subject.emtreeEnd stage renal disease
dc.subject.emtreeFemale
dc.subject.emtreeFlow rate
dc.subject.emtreeHeart left ventricle filling
dc.subject.emtreeHemodialysis
dc.subject.emtreeHuman
dc.subject.emtreeLung blood flow
dc.subject.emtreeMajor clinical study
dc.subject.emtreeMale
dc.subject.emtreeMitral valve
dc.subject.emtreePeak systolic velocity
dc.subject.emtreePulmonary vein
dc.subject.emtreeSystole
dc.subject.emtreeTissue doppler imaging
dc.subject.scopusCardiac; Hemodialysis; End Stage Renal Disease
dc.subject.wosMedicine, general & internal
dc.titleAcute haemodialysis-induced changes in tissue doppler echocardiography parameters
dc.typeArticle
dc.wos.quartileQ4 (Medicine, General & Internal)
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Kardiyoloji Ana Bilim Dalı
local.contributor.departmentTıp Fakültesi/Nefroloji Ana Bilim Dalı
local.indexed.atWOS
local.indexed.atScopus

Dosyalar

Orijinal seri

Şimdi gösteriliyor 1 - 1 / 1
Küçük Resim
Ad:
pdf_BMJ_292.pdf
Boyut:
180.93 KB
Format:
Adobe Portable Document Format
Açıklama

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Placeholder
Ad:
license.txt
Boyut:
1.71 KB
Format:
Item-specific license agreed upon to submission
Açıklama