Publication:
Multi-objective optimization of parameters affecting the performance of parabolic solar collectors by taguchi, anova, and grey relational analysis method

dc.contributor.authorDündar, Ahmet
dc.contributor.authorArslanoğlu, Nurullah
dc.contributor.buuauthorDÜNDAR, AHMET İHSAN
dc.contributor.buuauthorARSLANOĞLU, NURULLAH
dc.contributor.departmentMühendislik Fakültesi
dc.contributor.departmentMakine Mühendisliği Bölümü
dc.contributor.orcid0000-0003-4970-4490
dc.contributor.researcheridJWQ-6163-2024
dc.contributor.researcheridFXK-0953-2022
dc.date.accessioned2024-09-30T12:51:03Z
dc.date.available2024-09-30T12:51:03Z
dc.date.issued2023-01-01
dc.description.abstractIn this study, a combined simulation-optimization study was carried out on parabolic solar collectors. The parameters of energy and exergy efficiencies of parabolic solar collectors examined theoretically were optimized by the grey relational analysis method. A simulation model was developed to determine the performance of parabolic solar collectors. The results obtained from this model were shown to be in good agreement with the previous results in the literature. Four parameters such as wind speed, fluid flow rate, solar radiation value, and fluid inlet temperature were selected for statistical analysis. A statistical analysis was carried out to observe the effect of these parameters on the first- and second-law efficiencies of the collectors. Optimum values and contribution rates of the parameters were determined due to statistical analysis and optimization. As a result, the optimum conditions were obtained, i.e., wind speed value of 5 m/s, flow rate of 100 L/min, solar radiation value of 1000 W/m(2), and fluid inlet temperature value of 400 K. Under these conditions, energy and exergy efficiencies were found to be 73.34% and 20.53%, respectively. As a result of the statistical analysis, it was seen that the fluid inlet temperature was the most effective parameter with 72.81%. In addition, the effect rate of solar radiation value was 15.59%, the effect rate of fluid flow rate was 10.01%, and the effect rate of wind speed, which was the parameter with the lowest effect, was found to be 0.24%.
dc.identifier.eissn2162-6561
dc.identifier.endpage51
dc.identifier.issn1064-2285
dc.identifier.issue17
dc.identifier.startpage37
dc.identifier.urihttps://hdl.handle.net/11452/45533
dc.identifier.volume54
dc.identifier.wos001119796500003
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherBegell House Inc
dc.relation.journalHeat Transfer Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectParabolic solar collector
dc.subjectEnergy and exergy analyses
dc.subjectGrey relational analysis
dc.subjectScience & technology
dc.subjectPhysical sciences
dc.subjectThermodynamics
dc.titleMulti-objective optimization of parameters affecting the performance of parabolic solar collectors by taguchi, anova, and grey relational analysis method
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentMühendislik Fakültesi/Makine Mühendisliği Bölümü
relation.isAuthorOfPublication0c2d6e81-24f8-4d3e-b12d-2d4a432aabde
relation.isAuthorOfPublicatione4b32f7f-3d4a-4ebf-a8b5-7bbf2e7fcf3c
relation.isAuthorOfPublication.latestForDiscovery0c2d6e81-24f8-4d3e-b12d-2d4a432aabde

Files

Collections