Yayın:
Ventilation rates in large commercial layer hen houses with two-year continuous monitoring

dc.contributor.authorChai, Lilong
dc.contributor.authorNi, Ji Qin
dc.contributor.authorDiehl, Claude A.
dc.contributor.authorHeber, Albert J.
dc.contributor.authorChen, Yan
dc.contributor.authorCortus, Erin L.
dc.contributor.authorBogan, Bill W.
dc.contributor.authorLim, Tengteeh
dc.contributor.authorRamirez-Dorronsoro, Juan Carlos
dc.contributor.authorChen, Lide
dc.contributor.buuauthorKılıç, İlker
dc.contributor.departmentZiraat Fakültesi
dc.contributor.departmentBiyosistem Mühendisliği Bölümü
dc.contributor.orcid0000-0003-0087-6718
dc.contributor.researcheridAAG-8511-2021
dc.contributor.scopusid55156382800
dc.date.accessioned2022-02-24T11:23:55Z
dc.date.available2022-02-24T11:23:55Z
dc.date.issued2012
dc.description.abstract1. Ventilation controls the indoor environment and is critical for poultry production and welfare. Ventilation is also crucial for assessing aerial pollutant emissions from the poultry industry. Published ventilation data for commercial layer houses have been limited, and are mostly based on short-term studies, mainly because monitoring airflow from large numbers of fans is technically challenging. 2. A two-year continuous ventilation monitoring trial was conducted at two commercial manure belt houses (A and B), each with 250 000 layers and 88 130-cm exhaust fans. All the fans were individually monitored with fan rotational speed sensors or vibration sensors. Differential static pressures across the house walls were also measured. Three fan performance assessment methods were applied periodically to determine fan degradations. Fan models were developed to calculate house ventilations. 3. A total of 693 and 678 complete data days, each containing >16 h of valid ventilation data, were obtained in houses A and B, respectively. The two-year mean ventilation rates of houses A and B were 2.08 and 2.10 m(3) h(-1) hen(-1), corresponding to static pressures of -36.5 and -48.9 Pa, respectively. For monthly mean ventilation, the maximum rates were 4.87 and 5.01 m(3) h(-1) hen(-1) in July 2008, and the minimum were 0.59 and 0.81 m(3) h(-1) hen(-1) in February 2008, for houses A and B, respectively. 4. The two-year mean ventilation rates were similar to those from a survey in Germany and a 6-month study in Indiana, USA, but were much lower than the 8.4 and 6.2 m(3) h(-1) hen(-1) from a study in Italy. The minimum monthly mean ventilation rates were similar to the data obtained in winter in Canada, but were lower than the minimum ventilation suggested in the literature. The lower static pressure in house B required more ventilation energy input. The two houses, although identical, demonstrated differences in indoor environment controls that represented potential to increase ventilation energy efficiency, and reduce carbon footprints and operational costs.
dc.description.sponsorshipAgricultural Air Research Council
dc.description.sponsorshipAmerican Egg Board
dc.identifier.citationChai, L. vd. (2012). "Ventilation rates in large commercial layer hen houses with two-year continuous monitoring". British Poultry Science, 53(1), 19-31.
dc.identifier.doi10.1080/00071668.2011.643766
dc.identifier.endpage31
dc.identifier.issn0007-1668
dc.identifier.issn1466-1799
dc.identifier.issue1
dc.identifier.pubmed22404801
dc.identifier.scopus2-s2.0-84859206868
dc.identifier.startpage19
dc.identifier.urihttps://doi.org/10.1080/00071668.2011.643766
dc.identifier.urihttps://www.tandfonline.com/doi/full/10.1080/00071668.2011.643766
dc.identifier.urihttps://pubmed.ncbi.nlm.nih.gov/22404801/
dc.identifier.urihttp://hdl.handle.net/11452/24629
dc.identifier.volume53
dc.identifier.wos000304592400003
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherTaylor & Francis
dc.relation.collaborationYurt dışı
dc.relation.collaborationSanayi
dc.relation.journalBritish Poultry Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectAgriculture
dc.subjectEmissions
dc.subjectAmmonia
dc.subjectManure
dc.subjectFarms
dc.subjectEnvironment
dc.subjectBuildings
dc.subjectQuality
dc.subjectMethane
dc.subjectWelfare
dc.subject.scopusBarns; Swine Housing; Fans (Equipment)
dc.subject.wosAgriculture, dairy & animal science
dc.titleVentilation rates in large commercial layer hen houses with two-year continuous monitoring
dc.typeArticle
dc.wos.quartileQ2
dspace.entity.typePublication
local.contributor.departmentZiraat Fakültesi/Biyosistem Mühendisliği Bölümü
local.indexed.atPubMed
local.indexed.atWOS

Dosyalar

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Placeholder
Ad:
license.txt
Boyut:
1.71 KB
Format:
Item-specific license agreed upon to submission
Açıklama