Publication:
Atomic emission method with inductively coupled plasma for determining of noble metals (au, ag) in samples of industrial blister copper

dc.contributor.authorAubakirova, R. A.
dc.contributor.authorShomanova, Zh K.
dc.contributor.authorSafarov, R. Z.
dc.contributor.buuauthorAtasoy, Emin
dc.contributor.buuauthorATASOY, EMİN
dc.contributor.departmentEğitim Fakültesi
dc.contributor.departmentSosyal Bilimler Eğitimi
dc.date.accessioned2024-10-23T05:34:43Z
dc.date.available2024-10-23T05:34:43Z
dc.date.issued2019-01-01
dc.description.abstractIn the article weare presenting the results of investigation of AES ISP method for Au and Ag determination in samples of industrial blister copper. The developed method allows determining Au in the range 2856 g/ton, Ag - 2000-3000 g/ton. Control of precision was conducted using control analytical method (assay-gravimetric) as well as using measurement of state standard sample of copper content with attested values of impurities. The developed method is not inferior in metrological characteristics to control analytical method. Optimal spectral lines for Au - 242,795 nm and for Ag - 328,068 nm were selected because they have the most sensitivity and do not have spectral noises. Statistical processing of calibration characteristics for AES ISP determination of Ag and Au was conducted in accordance to RIS 54-2002. As a result, values of average standard relative deviations, the ratio of the average squared deviations and quantile of distribution were obtained. Parameters of precision, correctness, repeatability, reproducibility of the method were calculated according to RIS 61-2013.
dc.identifier.doi10.32014/2019.2518-1491.43
dc.identifier.endpage59
dc.identifier.issn2224-5286
dc.identifier.issue4
dc.identifier.startpage53
dc.identifier.urihttps://doi.org/10.32014/2019.2518-1491.43
dc.identifier.urihttps://hdl.handle.net/11452/46875
dc.identifier.wos000478012400009
dc.indexed.wosWOS.ESCI
dc.language.isoen
dc.publisherNatl Acad Sci Republic Kazakhstan
dc.relation.journalNews Of The National Academy Of Sciences Of The Republic Of Kazakhstan-series Chemistry And Technology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectGold
dc.subjectBlister copper
dc.subjectNoble metals
dc.subjectMelting
dc.subjectGold
dc.subjectSilver
dc.subjectAtomic emission
dc.subjectInductively coupled plasma
dc.subjectScience & technology
dc.subjectPhysical sciences
dc.subjectChemistry, multidisciplinary
dc.subjectChemistry
dc.titleAtomic emission method with inductively coupled plasma for determining of noble metals (au, ag) in samples of industrial blister copper
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentEğitim Fakültesi/Sosyal Bilimler Eğitimi
local.indexed.atWOS
relation.isAuthorOfPublication3faa3407-845a-4ffb-91c9-3b0b5703834e
relation.isAuthorOfPublication.latestForDiscovery3faa3407-845a-4ffb-91c9-3b0b5703834e

Files