Yayın: Effect of different arrangements of point source, aluminum absorber and detector on mass absorption coefficient of beta-particles
| dc.contributor.author | Yalçın, Sezai | |
| dc.contributor.buuauthor | Gürler, Orhan | |
| dc.contributor.department | Fen Edebiyat Fakültesi | |
| dc.contributor.researcherid | AAH-1837-2021 | |
| dc.contributor.scopusid | 11540936300 | |
| dc.date.accessioned | 2022-01-18T05:51:26Z | |
| dc.date.available | 2022-01-18T05:51:26Z | |
| dc.date.issued | 2005-11 | |
| dc.description.abstract | The transmission of 0.766 MeV beta-particles emitted from Tl-204 through aluminum has been investigated for different arrangements of point source, absorber and detector. In the first arrangement, the mass absorption coefficient (mu(m)) has been measured as a function of the absorber to the source distance (H-AS), when the absorber foil was placed just above the window of a surface barrier solid state detector. In the second arrangement, the mass absorption coefficient has been measured as a function of the absorber to detector distance (H-AD), when the absorber foil was placed just on the source. The measured mass absorption coefficients of beta-particles have been compared to the values gained in a previous work. | |
| dc.identifier.citation | Yalçın, S. ve Gürler, O. (2005). "Effect of different arrangements of point source, aluminum absorber and detector on mass absorption coefficient of beta-particles". Journal of Radioanalytical and Nuclear Chemistry, 266(3), 509-511. | |
| dc.identifier.doi | 10.1007/s10967-005-0941-0 | |
| dc.identifier.endpage | 511 | |
| dc.identifier.issn | 0236-5731 | |
| dc.identifier.issue | 3 | |
| dc.identifier.scopus | 2-s2.0-29144483296 | |
| dc.identifier.startpage | 509 | |
| dc.identifier.uri | https://doi.org/10.1007/s10967-005-0941-0 | |
| dc.identifier.uri | https://link.springer.com/article/10.1007%2Fs10967-005-0941-0 | |
| dc.identifier.uri | https://akjournals.com/view/journals/10967/266/3/article-p509.xml | |
| dc.identifier.uri | http://hdl.handle.net/11452/24128 | |
| dc.identifier.volume | 266 | |
| dc.identifier.wos | 000234024300024 | |
| dc.indexed.wos | SCIE | |
| dc.language.iso | en | |
| dc.publisher | Springer | |
| dc.relation.collaboration | Yurt içi | |
| dc.relation.journal | Journal of Radioanalytical and Nuclear Chemistry | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Chemistry | |
| dc.subject | Nuclear science & technology | |
| dc.subject | Low-energy positrons | |
| dc.subject | Thin metallic foils | |
| dc.subject | Transmission | |
| dc.subject | Electrons | |
| dc.subject | Penetration | |
| dc.subject | Al | |
| dc.subject | Cu | |
| dc.subject.emtree | Aluminum | |
| dc.subject.emtree | Thallium 204 | |
| dc.subject.emtree | Absorption | |
| dc.subject.emtree | Article | |
| dc.subject.emtree | Electron | |
| dc.subject.emtree | Molecular physics | |
| dc.subject.emtree | Radiochemistry | |
| dc.subject.emtree | Solid state | |
| dc.subject.scopus | Plane Source; Beta Particles; Proportional Counters | |
| dc.subject.wos | Chemistry, analytical | |
| dc.subject.wos | Chemistry, inorganic & nuclear | |
| dc.subject.wos | Nuclear science & technology | |
| dc.title | Effect of different arrangements of point source, aluminum absorber and detector on mass absorption coefficient of beta-particles | |
| dc.type | Article | |
| dc.wos.quartile | Q3 (Nuclear science & technology) | |
| dc.wos.quartile | Q4 | |
| dspace.entity.type | Publication | |
| local.contributor.department | Fen Edebiyat Fakültesi | |
| local.indexed.at | Scopus | |
| local.indexed.at | WOS |
Dosyalar
Lisanslı seri