Publication:
Arm circumference: Its importance for dialysis patients in the obesity era

dc.contributor.authorAkpolat, Tekin
dc.contributor.authorKaya, Coskun
dc.contributor.authorUtaş, Cengiz
dc.contributor.authorArınsoy, Turgay
dc.contributor.authorTaskapan, Hulya
dc.contributor.authorErdem, Emre
dc.contributor.authorYılmaz, M. Emin
dc.contributor.authorAtaman, Rezzan
dc.contributor.authorBozfakioglu, Semra
dc.contributor.authorÖzener, Cetin
dc.contributor.authorKarayaylalı, İbrahim
dc.contributor.authorKazancıoğlu, Rumeyza
dc.contributor.authorCamsarı, Taner
dc.contributor.authorErsoy, Fevzi
dc.contributor.authorDuman, Soner
dc.contributor.authorAteş, Kenan
dc.contributor.buuauthorYavuz, Mahmut
dc.contributor.buuauthorYAVUZ, MAHMUT
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentNefroloji Ana Bilim Dalı
dc.date.accessioned2024-08-16T06:07:06Z
dc.date.available2024-08-16T06:07:06Z
dc.date.issued2013-08-01
dc.description.abstractThe purposes of this study were to investigate the association between arm circumference and body mass index (BMI) and to discuss problems, mainly arm circumference and cuff size mismatch, that could affect the reliability of home blood pressure monitoring (HBPM) among peritoneal dialysis (PD) and hemodialysis (HD) patients.525 PD and 502 HD patients from 16 centers were included in the study. A two-part questionnaire was used to gather information from the participants. Arm circumferences were categorized into four groups according to the British Hypertension Society cuff size recommendations.Mean BMI and arm circumference of all participants were 25.0 kg/m(2) and 27.6 cm, respectively. There was a significant correlation between BMI and arm circumference. The mean BMI and arm circumference values were higher in PD patients than in HD patients. Requirement of a large-sized adult cuff was more common among PD patients compared to HD patients (14 % vs 8 %, p = 0.002).Since HBPM is a useful tool for clinicians to improve BP control, nephrologists should be aware of the problems related to HBPM in dialysis patients and take an active role to increase the reliability of HBPM.
dc.identifier.doi10.1007/s11255-012-0219-8
dc.identifier.endpage1110
dc.identifier.issn0301-1623
dc.identifier.issue4
dc.identifier.startpage1103
dc.identifier.urihttps://doi.org/10.1007/s11255-012-0219-8
dc.identifier.urihttps://hdl.handle.net/11452/44096
dc.identifier.volume45
dc.identifier.wos000322718000027
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherSpringer
dc.relation.journalInternational Urology And Nephrology
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectBlood-pressure-measurement
dc.subjectProtocol revision 2010
dc.subjectEuropean-society
dc.subjectInternational protocol
dc.subjectHome sphygmomanometers
dc.subjectHemodialysis patients
dc.subjectJapanese society
dc.subjectBody-mass
dc.subjectHypertension
dc.subjectValidation
dc.subjectArm circumference
dc.subjectCuff
dc.subjectHemodialysis
dc.subjectHome blood pressure monitoring
dc.subjectObesity
dc.subjectPeritoneal dialysis
dc.subjectScience & technology
dc.subjectLife sciences & biomedicine
dc.subjectUrology & nephrology
dc.titleArm circumference: Its importance for dialysis patients in the obesity era
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Nefroloji Ana Bilim Dalı
relation.isAuthorOfPublicationa096c377-129d-4ccb-94eb-205aaea33a01
relation.isAuthorOfPublication.latestForDiscoverya096c377-129d-4ccb-94eb-205aaea33a01

Files

Collections