Publication:
Determination of cadmium, chromium, lead, and mercury in polyethylene and polypropylene after xylene treatment by energy dispersive x-ray fluorescence spectrometry

dc.contributor.authorÇimenoǧlu, Mehmet Akif
dc.contributor.buuauthorGüçer, Şeref
dc.contributor.buuauthorÖzer, Elif Tumay
dc.contributor.departmentFen Edebiyat Fakültesi
dc.contributor.departmentKimya Bölümü
dc.contributor.orcid0000-0003-0610-2019
dc.contributor.researcheridAAI-3137-2021
dc.contributor.scopusid36849130600
dc.contributor.scopusid37047586000
dc.date.accessioned2021-12-24T13:31:07Z
dc.date.available2021-12-24T13:31:07Z
dc.date.issued2011
dc.description.abstractA convenient organic solvent treatment method was developed for the determination of Cd, Cr, Hg, and Pb in polyethylene and polypropylene matrices by energy dispersive X-ray fluorescence spectrometry. The solvent treatment method had many advantages for the fast, simple, and accurate multi-element analysis of these materials. Calibration curves were prepared using organometallic compounds in xylene in the concentration range of 1-80 mg kg(-1). The prepared samples had a homogeneous elemental distribution and good durability. The trueness for the quantification of mentioned elements were checked by using a polyethylene certified reference material. The apparent recoveries of the elements with certified values were in the range of 0.81 (Hg) to 1.14 (Pb). The precision was normally better than 8% RSD, with the exception of Hg (10%). The method detection limits were found to be 12, 24, 12, and 12 mg kg(-1) for Cd, Cr, Hg, and Pb, respectively. Polyethylene and polypropylene samples were analyzed by both the XRF method and the reference technique for comparative purposes. Application of analysis of variance (ANOVA) showed no differences between the mean results. The proposed method could be also applied to several different xylene soluble plastics.
dc.identifier.citationÖzer, E. T. vd. (2011). ''Determination of cadmium, chromium, lead, and mercury in polyethylene and polypropylene after xylene treatment by energy dispersive x-ray fluorescence spectrometry". Instrumentation Science and Technology, 39(4), 357-367.
dc.identifier.endpage367
dc.identifier.issn1073-9149
dc.identifier.issue4
dc.identifier.scopus2-s2.0-79960798875
dc.identifier.startpage357
dc.identifier.urihttps://doi.org/10.1080/10739149.2011.585194
dc.identifier.urihttps://www.tandfonline.com/doi/full/10.1080/10739149.2011.585194
dc.identifier.urihttp://hdl.handle.net/11452/23622
dc.identifier.volume39
dc.identifier.wos000299740700002
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherTaylor & Francis
dc.relation.bapF-2008/57
dc.relation.collaborationSanayi
dc.relation.journalInstrumentation Science and Technology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectChemistry
dc.subjectInstruments & instrumentation
dc.subjectEDXRF
dc.subjectHeavy metals
dc.subjectPlastics
dc.subjectAtomic emission-spectrometry
dc.subjectTrace-element determinations
dc.subjectMass-spectrometry
dc.subjectPlastic materials
dc.subjectQuality-control
dc.subjectPackaging materials
dc.subjectHeavy-metals
dc.subjectPolymers
dc.subjectAdditives
dc.subjectWaste
dc.subjectCadmium
dc.subjectChromium
dc.subjectElastomers
dc.subjectEnergy dispersive spectroscopy
dc.subjectFluorescence
dc.subjectFluorescence spectroscopy
dc.subjectLead
dc.subjectMeasurement theory
dc.subjectMercury (metal)
dc.subjectOrganic solvents
dc.subjectOrganometallics
dc.subjectPlastic products
dc.subjectPolyethylenes
dc.subjectPolypropylenes
dc.subjectSpectrometry
dc.subjectThermoplastics
dc.subjectXylene
dc.subjectApparent recovery
dc.subjectCalibration curves
dc.subjectCertified reference materials
dc.subjectCertified values
dc.subjectConcentration ranges
dc.subjectEDXRF
dc.subjectElemental distribution
dc.subjectEnergy dispersive x-ray fluorescence spectrometries
dc.subjectGood durability
dc.subjectMethod detection limits
dc.subjectMultielement analysis
dc.subjectOrganometallic compounds
dc.subjectPolypropylene matrices
dc.subjectReference technique
dc.subjectSolvent treatment
dc.subjectAnalysis of variance (ANOVA)
dc.subject.scopusIsotope Dilution Technique; Cadmium-111; Interlaboratory Comparison
dc.subject.wosChemistry, analytical
dc.subject.wosInstruments & instrumentation
dc.titleDetermination of cadmium, chromium, lead, and mercury in polyethylene and polypropylene after xylene treatment by energy dispersive x-ray fluorescence spectrometry
dc.typeArticle
dc.wos.quartileQ4
dspace.entity.typePublication
local.contributor.departmentFen Edebiyat Fakültesi/Kimya Bölümü
local.indexed.atScopus
local.indexed.atWOS

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: