Yayın:
Evaluation of an ultraviolet room disinfection protocol to decrease nursing home microbial burden, infection and hospitalization rates

dc.contributor.authorKovach, Christine R.
dc.contributor.authorNeiman, Tammy
dc.contributor.authorDyer, Elaine M.
dc.contributor.authorArzaga, Alvin Jason A.
dc.contributor.authorKelber, Sheryl T
dc.contributor.buuauthorTaneli, Yavuz
dc.contributor.departmentMühendislik Fakültesi
dc.contributor.departmentMimarlık Bölümü
dc.contributor.orcid0000-0003-0349-1098
dc.contributor.researcheridC-3035-2008
dc.contributor.scopusid36544397500
dc.date.accessioned2022-12-26T11:11:39Z
dc.date.available2022-12-26T11:11:39Z
dc.date.issued2017-02-21
dc.description.abstractBackground: The focus of nursing home infection control procedures has been on decreasing transmission between healthcare workers and residents. Less evidence is available regarding whether decontamination of high-touch environmental surfaces impacts infection rates or resident outcomes. The purpose of this study was to examine if ultraviolet disinfection is associated with changes in: 1) microbial counts and adenosine triphosphate counts on hightouch surfaces; and 2) facility wide nursing home acquired infection rates, and infection-related hospitalization. Methods: The study was conducted in one 160-bed long-term care facility. Following discharge of each resident, their room was cleaned and then disinfected using a newly acquired ultraviolet light disinfection device. Shared living spaces received weekly ultraviolet light disinfection. Thirty-six months of pretest infection and hospitalization data were compared with 12 months of posttest data. Pre and posttest cultures were taken from high-touch surfaces, and luminometer readings of adenosine triphosphate were done. Nursing home acquired infection rates were analyzed relative to hospital acquired infection rates using analysis of variance procedures. Wilcoxon signed rank tests, The Cochran's Q, and Chi Square were also used. Results: There were statistically significant decreases in adenosine triphosphate readings on all high-touch surfaces after cleaning and disinfection. Culture results were positive for gram-positive cocci or rods on 33% (n = 30) of the 90 surfaces swabbed at baseline. After disinfectant cleaning, 6 of 90 samples (7.1%) tested positive for a gram-positive bacilli, and after ultraviolet disinfection 4 of the 90 samples (4.4%) were positive. There were significant decreases in nursing home acquired relative to hospital-acquired infection rates for the total infections (p = .004), urinary tract infection rates (p = .014), respiratory system infection rates (p = .017) and for rates of infection of the skin and soft tissues (p = .014). Hospitalizations for infection decreased significantly, with a notable decrease in hospitalization for pneumonia (p = .006). Conclusions: This study provides evidence that the pulsed-xenon ultraviolet disinfection device is superior to manual cleaning alone for decreasing microbes on environmental surfaces, as well as decreasing infection rates, and the rates of hospitalization for infection. Results suggest that placing a stronger emphasis on environmental surface disinfection in long-term care facilities may decrease nursing home acquired infections.
dc.description.sponsorshipJewish Home Foundation
dc.identifier.citationKovach, C. R. vd. (2017). ''Evaluation of an ultraviolet room disinfection protocol to decrease nursing home microbial burden, infection and hospitalization rates''. BMC Infectious Diseases, 17, 186.
dc.identifier.doi10.1186/s12879-017-2275-2
dc.identifier.issn1471-2334
dc.identifier.pubmed28253849
dc.identifier.scopus2-s2.0-85014332056
dc.identifier.startpage186
dc.identifier.urihttps://doi.org/10.1186/s12879-017-2275-2
dc.identifier.urihttps://bmcinfectdis.biomedcentral.com/articles/10.1186/s12879-017-2275-2
dc.identifier.urihttp://hdl.handle.net/11452/30088
dc.identifier.volume17
dc.identifier.wos000397391700001
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherBMC Campus
dc.relation.collaborationYurt dışı
dc.relation.collaborationSanayi
dc.relation.journalBMC Infectious Diseases
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectInfectious diseases
dc.subjectEnvironment
dc.subjectInfection
dc.subjectLong-term care
dc.subjectNursing home
dc.subjectPneumonia
dc.subjectPrevention
dc.subjectClostridium-difficile
dc.subjectEnvironmental contamination
dc.subjectLong
dc.subjectSurvival
dc.subjectBacteria
dc.subjectFabrics
dc.subjectImpact
dc.subject.emtreeAdenosine triphosphate
dc.subject.emtreeXenon
dc.subject.emtreeArticle
dc.subject.emtreeCleaning
dc.subject.emtreeCcontrolled study
dc.subject.emtreeDisinfection
dc.subject.emtreeGram positive bacterium
dc.subject.emtreeGram positive cocci
dc.subject.emtreeHospital discharge
dc.subject.emtreeHospital infection
dc.subject.emtreeHospitalization
dc.subject.emtreeHuma
dc.subject.emtreeNursing home
dc.subject.emtreePathogen load
dc.subject.emtreeRadiation equipment
dc.subject.emtreeRespiratory tract infection
dc.subject.emtreeSkin infection
dc.subject.emtreeSoft tissue infection
dc.subject.emtreeUltraviolet radiation
dc.subject.emtreeUrinary tract infection
dc.subject.emtreeBacterial load
dc.subject.emtreeCross infection
dc.subject.emtreeDisinfection
dc.subject.emtreeEvaluation study
dc.subject.emtreeFollow up
dc.subject.emtreeHospitalization
dc.subject.emtreeOutcome assessment
dc.subject.emtreeprocedures
dc.subject.emtreeRadiation response
dc.subject.emtreeStatistics and numerical data
dc.subject.emtreeUnited states
dc.subject.meshBacterial load
dc.subject.meshCross infection
dc.subject.meshDisinfection
dc.subject.meshFollow-up studies
dc.subject.meshHospitalization
dc.subject.meshHumans
dc.subject.meshMidwestern united states
dc.subject.meshNursing homes
dc.subject.meshOutcome assessment (Health Care)
dc.subject.meshUltraviolet rays
dc.subject.meshXenon
dc.subject.scopusDisinfection; Biocide; Healthcare Associated Infection
dc.subject.wosInfectious diseases
dc.titleEvaluation of an ultraviolet room disinfection protocol to decrease nursing home microbial burden, infection and hospitalization rates
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentMühendislik Fakültesi/Mimarlık Bölümü
local.indexed.atScopus
local.indexed.atWOS

Dosyalar

Orijinal seri

Şimdi gösteriliyor 1 - 1 / 1
Küçük Resim
Ad:
Yavuz_vd_2017.pdf
Boyut:
790.31 KB
Format:
Adobe Portable Document Format
Açıklama

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Placeholder
Ad:
license.txt
Boyut:
1.71 KB
Format:
Item-specific license agreed upon to submission
Açıklama