dc.description.abstractBACKGROUND AND OBJECTIVE: To compare the intraocular pressures (IOP) obtained with dynamic contour tonometry (DCT) and Goldmann applanation tos.nometry (GAT) and to determine the dependency of both devices on corneal structure. PATIENTS AND METHODS: One hundred forty eyes of 70 patients were included. Cases with corneal pathologies, former glaucoma diagnosis, and systemic diseases were excluded. All eyes underwent measurements of central corneal thickness (CCT) and corneal curvature. IOP measurements were obtained with GAT and DCT. The agreement of measurements was statistically analyzed. RESULTS: The correlation of IOP values obtained with DCT and GAT was statistically significant. The mean DCT values were 0.46 +/- 2.55 mm Hg higher than those of GAT, but this difference was statistically insignificant. Bland-Altman plots showed reasonable inter-method agreement between DCT and GAT measurements. GAT readings were significantly affected by CCT, but DCT measurements were affected by age and corneal curvature. CONCLUSION: DCT is a reliable method of assessing IOP and is less dependent on central corneal thickness. This new technology may be a promising step forward in the management of glaucoma. Further studies are required to validate these observation
dc.identifier.citationYalçınbayır, Ö. vd. (2010). "A clinical comparison of dynamic contour tonometry versus goldmann applanation tonometry". Ophthalmic Surgery Lasers and Imaging, 41(4), 437-442.
dc.identifier.doi10.3928/15428877-20100426-01
dc.identifier.endpage442
dc.identifier.issn1542-8877
dc.identifier.issn1938-2375
dc.identifier.issue4
dc.identifier.pubmed20438047
dc.identifier.scopus2-s2.0-77955877131
dc.identifier.startpage437
dc.identifier.urihttps://doi.org/10.3928/15428877-20100426-01
dc.identifier.urihttps://pubmed.ncbi.nlm.nih.gov/20438047/
dc.identifier.urihttp://hdl.handle.net/11452/24381
dc.identifier.volume41
dc.identifier.wos000280177900006
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherSlack
dc.relation.bapT-2005/8
dc.relation.journalOphthalmic Surgery Lasers and Imaging
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCentral corneal thickness
dc.subjectOcular pulse amplitude
dc.subjectIntraocular-pressure
dc.subjectHealthy-subjects
dc.subjectGlaucoma
dc.subjectHypertension
dc.subjectEyes
dc.subjectOphthalmology
dc.subjectSurgery
dc.subject.emtreeAdult
dc.subject.emtreeAged
dc.subject.emtreeArticle
dc.subject.emtreeClinical assessment
dc.subject.emtreeControlled study
dc.subject.emtreeCornea curvature
dc.subject.emtreeCornea thickness
dc.subject.emtreeCorrelation analysis
dc.subject.emtreeDynamic contour tonometry
dc.subject.emtreeFemale
dc.subject.emtreeGlaucoma
dc.subject.emtreeGoldmann applanation tonometry
dc.subject.emtreeHuman
dc.subject.emtreeIntermethod comparison
dc.subject.emtreeIntraocular pressure
dc.subject.emtreeMajor clinical study
dc.subject.emtreeMale
dc.subject.emtreeMeasurement
dc.subject.emtreeOutcome assessment
dc.subject.emtreePriority journal
dc.subject.emtreeReliability
dc.subject.emtreeStatistical significance
dc.subject.emtreeTonometry
dc.subject.emtreeVisual acuity
dc.subject.meshAdult
dc.subject.meshAged
dc.subject.meshCornea
dc.subject.meshCross-sectional studies
dc.subject.meshFemale
dc.subject.meshGlaucoma
dc.subject.meshHumans
dc.subject.meshIntraocular pressure
dc.subject.meshMale
dc.subject.meshMiddle aged
dc.subject.meshProspective studies
dc.subject.meshReference values
dc.subject.meshReproducibility of results
dc.subject.meshTonometry, ocular
dc.subject.scopusIntraocular Pressure; Tonometry; Keratoconus
dc.subject.wosOphthalmology
dc.subject.wosSurgery
dc.titleA clinical comparison of dynamic contour tonometry versus goldmann applanation tonometry
dc.typeArticle
dc.wos.quartileQ4
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Göz Hastalıkları Ana Bilim Dalı
local.indexed.atScopus
local.indexed.atWOS

Dosyalar

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Placeholder
Ad:
license.txt
Boyut:
1.71 KB
Format:
Item-specific license agreed upon to submission
Açıklama