Yayın: Tracheal intubation using the ILMA, C-Trach (TM) or McCoy laryngoscope in patients with simulated cervical spine injury
| dc.contributor.buuauthor | Bilgin, Hülya | |
| dc.contributor.buuauthor | Bozkurt, M. | |
| dc.contributor.department | Tıp Fakültesi | |
| dc.contributor.department | Anesteziyoloji ve Yoğun Bakım Ana Bilim Dalı | |
| dc.contributor.orcid | 0000-0001-6639-5533 | |
| dc.contributor.researcherid | A-7338-2016 | |
| dc.contributor.scopusid | 6701663354 | |
| dc.contributor.scopusid | 16202046200 | |
| dc.date.accessioned | 2021-10-01T12:27:25Z | |
| dc.date.available | 2021-10-01T12:27:25Z | |
| dc.date.issued | 2006 | |
| dc.description.abstract | A study of 90 patients was undertaken to compare intubation success rates of using either ILMA, C-Trach(TM) or McCoy laryngoscope in patients with simulated cervical spine injury. Insertion and intubation success rates, time taken to achieve intubation, airway complications and haemodynamic parameters were recorded. Insertion of ILMA and C-Trach(TM) was successful at the first attempt in all patients. Intubation success rates were higher in the C-Trach (100%) and McCoy (100%) groups than in the ILMA (87%) group. Total intubation time was significantly longer in the ILMA (63 s, SD 36.5) group than in the C-Trach (41 s, SD 15.8) and McCoy (30 s, SD 7.4) groups (p < 0.05, p < 0.05, respectively). There were no significant differences in haemodynamic parameters among the groups at any time. | |
| dc.identifier.citation | Bilgin, H. ve Bozkurt, M. (2006). ''Tracheal intubation using the ILMA, C-Trach (TM) or McCoy laryngoscope in patients with simulated cervical spine injury''. Anaesthesia, 61(7), 685-691. | |
| dc.identifier.doi | 10.1111/j.1365-2044.2006.04706.x | |
| dc.identifier.endpage | 691 | |
| dc.identifier.issn | 0003-2409 | |
| dc.identifier.issue | 7 | |
| dc.identifier.pubmed | 16792615 | |
| dc.identifier.scopus | 2-s2.0-33745040992 | |
| dc.identifier.startpage | 685 | |
| dc.identifier.uri | https://doi.org/10.1111/j.1365-2044.2006.04706.x | |
| dc.identifier.uri | https://associationofanaesthetists-publications.onlinelibrary.wiley.com/doi/10.1111/j.1365-2044.2006.04706.x | |
| dc.identifier.uri | http://hdl.handle.net/11452/22184 | |
| dc.identifier.volume | 61 | |
| dc.identifier.wos | 000238914200011 | |
| dc.indexed.wos | SCIE | |
| dc.language.iso | en | |
| dc.publisher | Wiley | |
| dc.relation.journal | Anaesthesia | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Anesthesiology | |
| dc.subject | C-Trach | |
| dc.subject | McCoy | |
| dc.subject | Ilma | |
| dc.subject | Blade | |
| dc.subject | Pacement | |
| dc.subject | Blind | |
| dc.subject | Macintosh | |
| dc.subject | Awake intubation | |
| dc.subject | Neck stabilization | |
| dc.subject | Levering laryngoscope | |
| dc.subject | Endotracheal intubation | |
| dc.subject | Laryngeal mask airway | |
| dc.subject.emtree | Sevoflurane | |
| dc.subject.emtree | Rocuronium | |
| dc.subject.emtree | Propofol | |
| dc.subject.emtree | Oxygen | |
| dc.subject.emtree | Midazolam | |
| dc.subject.emtree | Lidocaine | |
| dc.subject.emtree | Fentanyl | |
| dc.subject.emtree | Spine stabilization | |
| dc.subject.emtree | Male | |
| dc.subject.emtree | Major clinical study | |
| dc.subject.emtree | Laryngoscope | |
| dc.subject.emtree | Intermethod comparison | |
| dc.subject.emtree | Human | |
| dc.subject.emtree | Hemodynamic parameters | |
| dc.subject.emtree | Female | |
| dc.subject.emtree | Endotracheal intubation | |
| dc.subject.emtree | Elective surgery | |
| dc.subject.emtree | Disease simulation | |
| dc.subject.emtree | Controlled study | |
| dc.subject.emtree | Cervical spine injury | |
| dc.subject.emtree | Artificial ventilation | |
| dc.subject.emtree | Article | |
| dc.subject.emtree | Anesthesia induction | |
| dc.subject.emtree | Adult | |
| dc.subject.mesh | Trachea | |
| dc.subject.mesh | Time factors | |
| dc.subject.mesh | Pharyngitis | |
| dc.subject.mesh | Middle aged | |
| dc.subject.mesh | Male | |
| dc.subject.mesh | Laryngoscopes | |
| dc.subject.mesh | Intratracheal | |
| dc.subject.mesh | Intubation | |
| dc.subject.mesh | Humans | |
| dc.subject.mesh | Heart rate | |
| dc.subject.mesh | Female | |
| dc.subject.mesh | Cervical vertebrae | |
| dc.subject.mesh | Blood pressure | |
| dc.subject.mesh | Anesthesia, general | |
| dc.subject.mesh | Aged | |
| dc.subject.mesh | Adult | |
| dc.subject.scopus | Macintosh; Laryngoscopes; Intubation | |
| dc.subject.wos | Anesthesiology | |
| dc.title | Tracheal intubation using the ILMA, C-Trach (TM) or McCoy laryngoscope in patients with simulated cervical spine injury | |
| dc.type | Article | |
| dc.wos.quartile | Q2 | |
| dspace.entity.type | Publication | |
| local.contributor.department | Tıp Fakültesi/Anesteziyoloji ve Yoğun Bakım Ana Bilim Dalı | |
| local.indexed.at | PubMed | |
| local.indexed.at | WOS |
Dosyalar
Lisanslı seri
1 - 1 / 1
